Panasonic KX-TVS80 ユーザーズマニュアル
7.5
SPECIFICATIONS
162
SYSTEM MAINTENANCE AND TROUBLESHOOTING
7.5
SPECIFICATIONS
Table 31
Port:
2 Digital/Analog ports
Dialing Method:
DTMF/Pulse (10/20 pps)
Flash Time:
100/300/600/900 ms (programmable)
CPC Detection
6.5/150/300/450/600 ms (programmable)
Type of Line:
Loop start minimum Loop Current: 20 mA
minimum Line Voltage: 7 V DC
minimum Ringing Voltage: 40 V AC
minimum Ringing Voltage: 40 V AC
Extension Numbering:
2 to 5 digits (programmable)
Pause Time:
1 to 9 s (programmable)
Message Waiting Lamp:
Programmable DTMF sequence.
Main CPU:
16-bit microprocessor
Capacity for Flash Memory:
TVS50: 2 h (expandable)
TVS80: 6 h (non-expandable)
TVS80: 6 h (non-expandable)
Number of Mailboxes:
TVS50: Max. 32
TVS80: Max. 64
(including System Manager and Message Manager
mailboxes)
TVS80: Max. 64
(including System Manager and Message Manager
mailboxes)
Number of Messages:
Max. 100 per mailbox (programmable)
Personal Greeting Message Length:
8 to 60 s (programmable)
Message Retention Time:
1 to 30 days or unlimited (programmable)
Maximum Message Length:
1 to 6 min (programmable)
Reports:
Mailbox Assignment, COS (Class of Service) Assignment,
System Service Report, Call Account Report, Port Usage
Report, Flash Memory Usage Report, Mailbox Usage
Report, FAX Call Report
System Service Report, Call Account Report, Port Usage
Report, Flash Memory Usage Report, Mailbox Usage
Report, FAX Call Report
Connections
Telephone Line:
Modular connectors 2
In case of Inband, 2-conductor wire 2
In case of APT, 4-conductor wire with APT interface 2
In case of DPT, 4-conductor wire with DPT interface 1
In case of Inband, 2-conductor wire 2
In case of APT, 4-conductor wire with APT interface 2
In case of DPT, 4-conductor wire with DPT interface 1
Data Port:
RS-232C interface port
Environmental Requirements:
0 - 40 °C {32 - 104 °F}, 10 - 90 % relative humidity
Power Source:
120 V AC, 60 Hz
Power Consumption:
Approx. 10 W