Page 22
4.2 
Restarting the System (Clear Memory) 
Menu
To remove all labeling, programming, assignments 
and temperature settings, highlight MENU and 
press SELECT. Highlight SYSTEM SETUP 
and press SELECT (see Figure 30). Highlight 
CLEAR MEMORY and press SELECT. Highlight 
CONTINUE and press SELECT. Use the UP or 
DOWN button to highlight YES or NO and press 
SELECT. There will be about a 15 second delay 
before you see the FINISHED screen. Highlight 
CONTINUE and press SELECT to return to the 
SYS TEM  SETUP. 
  CAUTION
In service mode, equipment protection safety 
interlocks are overridden.
MAIN MENU
HELP
PROGRAM
SET  TEMP
SET  TIME
PDA OPTIONS
SYSTEM   SETUP
SYSTEM SETUP
SOLAR PRIORITY
PUMP LOCKOUT
ASSIGN JVAs
COLOR LIGHTS
SPA SWITCH
SERVICE INFO
CLEAR MEMORY
HEAT PUMP
MORE
CLEAR MEMORY
WARNING
Clearing memory
erases ALL
stored settings.
CONTINUE
CLEAR MEMORY
FINAL WARNING
Are you SURE
that you want to 
ERASE ALL
SETTINGS
??
YES
NO
CLEAR MEMORY
FINISHED
Press SELECT
to continue.
CONTINUE
CLEAR MEMORY
ERASING
ALL
SETTINGS
please wait
Figure 30.  Clear Memory Menu
4.3 
PDA System Defaults and General Modes
Default Temperature (Pool/Spa Combination)
Default Pool Temp = 80° F
Default Spa Temp = 102° F
Default Temperature (Pool/Spa Only)
Default TEMP1 = 80° F
Default TEMP2 = 60° F
Default Spa Side Switch Settings
Button 1 = Spa (Filter Pump for pool/spa only models)
Button 2 = Spa Heater (Temp1 pool/spa only models)
Button 3 = AUX1
Button 4 = AUX2
Default Freeze Protection Settings
Filter Pump: Freeze Protection ON. 
All Other Equipment: Freeze Protection OFF
Default Activation Temperature: 38° F
NOTE  If you select SPA to be freeze protected, water 
circulation will switch between pool and spa 
every 30 minutes during freezing conditions 
once freeze mode is active.
4.3.1  Power Center Service Switch
AUTO Mode (automatic) 
1.  The PDA Handheld Remote has complete 
control of all functions. 
2.  All programmed settings will operate. 
3.  All safety delays and equipment protection 
in ter locks  are  operational.
SERVICE Mode
1.  The power center has complete control of 
all functions. 
2.  Service mode must be turned on/off at the 
power center. 
3.  No programmed settings will work.
TIMEOUT Mode
1.  The power center has complete control for 
three (3) hours.  
2.  After three (3) hours the system will return 
to AUTO mode. 
3.  Programmed on/off times will be 
overridden during the three (3) hours.
4.  After the three (3) hour "time out", the 
system will resume any programmed items 
that were overridden.