Kathrein AOP 52 ユーザーズマニュアル

ページ / 6
935.543/
C
/0707
/3.3e/ZWT
Internet: http://www.kathrein.de
KATHREIN-Werke KG  .  Anton-Kathrein-Straße 1 – 3  .  Postfach 10 04 44  .  D-83004 Rosenheim  .  Deutschland  .  Telefon (0 80 31) 1 84-0  .  Fax (0 80 31) 1 84-3 06
Abb. 6: Horizontal alignment
Abb. 7: Vertical alignment
Technical data of the antennas
Type
AOP 52
AOS 32
AOS 65
AOT 65
Order Number
212347
212349
212352
212353
Channels
21...52
21...32
21...65
21...65
Gain
dB
11...15
15,5...17
11...17
12...18
Reception range
MHz
470...726
470...566
470...830
470...830
Full width at half maximum
horiz.°
43...26
26...21
43...21
37...18
vert.°
52...32
30...23
47...23
39...19
Front-to-back-ratio
dB
24...30
27...31
25...32
23...32
Mast clamp range
mm Ø
22...60
Length
mm
1380
2830
2240
2820
Wind load at 800 N/m
2
N
108
203
179
192
Limiting wind load at 1100 N/m
2
N
148
287
246
263
Packing unit/weight
St./kg
1/2,3
1/3,8
1/3,5
1/3,7
Packing unit dimensions
mm
890 x 520 x 100
1080 x 520 x 130
960 x 520 x 130
1080 x 520 x 130
Overview of the Kathrein antenna masts
Type
ZSD 48
ZSF 47
ZSF 48
ZSH 47
ZSH 48
ZSH 59
ZSH 62
2
)
Order Number
218380
218385
218381
218386
218394
218382
218383
Lenght L
L/m
2 x 2 = 4
2 x 2,5 = 5
2 x 3 = 6
Diameter D
1
/D
2
D
1
/D
2
/mm
40/48
40/48
40/48
40/48
40/48
48/60
48/60
Cable entry points
3
-
3
-
3
5
5
Quality category (steel)
St 52
St 37
St 52
St 37
St 52
St 52
St 52
Wall thickness in clamping range
mm
2,5
2
2,5
2
2,5
2,5
4,5
Allowable bending moment 
1
),
5,0 m
-
-
-
320
850
1150
1950 
(1150)
Effective length at 800 N/m
2
4,0 m
-
500
1040
430
960
1280
2120 
(1280)
3,0 m
1170
540
1080
-
-
-
-
Allowable bending moment 1),
5,0 m
-
-
-
160
700
900
1700 (900)
Effectice length at 800 N/m
2
4,0 m
-
390
920
300
840
1080
1960 (1080)
3,0 m
1110
480
1000
-
-
-
-
Packing unit/weight
kg
1/11,4
1/11,3
1/14,2
1/13,1
1/17,8
1/20,5
1/37,5
1
)  The maximum allowable moment on the clamping point applies for the appropriate effectice length. The wind load absorption of the tube has already been allowed for. The 
bold values apply for an ordinary wind load (q = 800 N/m
2
). In case of increased wind load (q = 1100 N/m
2
), the reduced values apply.
  According to EN 50083-1, the mast clamping length must be at least 1/6 of the mast length.
2
)  The technical data underlie the computation base according to DIN 4131.
  If the sum of the antenna wind load moments exceeds the values put in parentheses (
≙ 1650 Nm am Einspannpunkt), a structural analysis is required, according to EN 
50083, part 1.