Polycom DOC2702A ユーザーズマニュアル

ページ / 1010
Chapter 23-RMX Hardware Monitoring
Polycom, Inc.
23-17
2
Click the Event Log tab to view a log of events that were recorded by the system for the 
RMX.
The logged events can be saved to a *.xls file by clicking the Save Event Log button. It is 
not possible to save individual or multiple selected events; the entire log file must be 
saved.
  
Part Number
The chassis part number. The Part Number contains the letter A/B/C/
D that represents the chassis type. 
Card Type
The name of the hardware product or component, i.e. RMX 4000, 
Backplane.
Chassis HW Version
Indicates the MCU’s current chassis hardware version.
Turn SSH
Enables/disables the SSH monitor. This is a secured terminal 
enabling access to the operating system in order to define Linux 
commands.
Table 23-13 
MCU Properties - General Info (Continued)
Field
Description
Table 23-14 
MCU Properties - Event Log
Column
Description
Record ID
The recorded ID number of the logged event.
Time Stamp
Lists the date and time that the event occurred.
Type
Displays the type of event recorded in the log.
Sensor Number
The number of the LED sensor on the RMX unit.
Sensor Description
Describes which sensor the event is being logged.
Status
The sensor’s active status.
Ipmb Address(hex)
Contains all the internal IPMI network addresses on the IPMB bus, i.e. 
0x20 (Switch), 0x86 (MFA), etc...