Mitsubishi Electronics A1SJ61BT11 ユーザーズマニュアル
8 - 14
8 PROGRAMMING
MELSEC-QnA
Table 8.1 Link special relay list (continued)
Availability
( : available,
: not available )
: not available )
Online
Number Name
Description
Master
station
Local
station
Offline
SB004C 1
Line test acceptance
status
status
Indicates the line test request acceptance status.
OFF : Not executed
ON :
ON :
Specification
accepted
SB004D 1 Line test complete status
Indicates the line test complete status.
OFF : Not completed
ON :
ON :
Test
complete
SB004E 1
Parameter setting test
acceptance status
acceptance status
Indicates the parameter setting test request acceptance status.
OFF : Not accepted
ON :
ON :
Specification
accepted
SB004F 1
Parameter setting test
complete status
complete status
Indicates the parameter setting test complete status.
OFF : Not completed
ON :
ON :
Test
complete
SB0050
Offline test status
Indicates the offline-test execution status.
OFF : Not executed
ON : In progress
ON : In progress
SB0060 Mode
Indicates the module's mode setting switch setting status.
OFF : Online (0)
ON : Other than online (0)
ON : Other than online (0)
SB0061 Station
type
Indicates the setting status of the module station number setting
switch.
switch.
OFF : Master station (station number 0)
ON : Local station (station numbers 1 to 64)
ON : Local station (station numbers 1 to 64)
SB0062 1
Standby master station
setting
setting
Indicates the setting status of the standby master station.
OFF : Not set
ON :
ON :
Set
SB0065
Input data status of a data
link error station
link error station
Indicates the setting status of the module's condition setting switch
(DIP switch) SW4.
(DIP switch) SW4.
OFF : Clear
ON :
ON :
Keep
Indicates the setting of the module's condition setting switch (DIP
switch) SW5, SW6.
switch) SW5, SW6.
SB0066
Number of
occupied stations
SB0066 (SW5)
SB0067 (SW6)
1
station
OFF
OFF
2
stations
OFF
ON
3
stations
ON
ON
SB0067 2
4
stations
ON
OFF
Number of occupied
stations
stations
SB0069 Module
mode
Indicates the setting status of the module's condition setting switch
(DIP switch) SW8. (Usable on AJ61BT11 and A1SJ61BT11)
(DIP switch) SW8. (Usable on AJ61BT11 and A1SJ61BT11)
OFF : Intelligent mode
ON : I/O mode
ON : I/O mode
SB006A
Switch setting status
Indicates the switch setting status.
OFF : Normal
ON : Setting error exists (Store the error code in SW006A)
ON : Setting error exists (Store the error code in SW006A)
SB006D
Parameter setting status
Indicates the parameter setting status.
OFF : Normal
ON : Setting error exists (Store the error code in SW0068)
ON : Setting error exists (Store the error code in SW0068)
SB006E
Host station operation
status
status
Indicates the data link communication status with other stations.
OFF : In operation
ON : Not in operation
ON : Not in operation
SB0070 1
Master station data link
status
status
Indicates data link status.
OFF : Data link for master station
ON : Data link for waiting master station
ON : Data link for waiting master station
SB0071 1
Standby master station
information
information
Indicates whether there is standby master station or not.
OFF : Not present
ON :
ON :
Present
SB0072 1 Scan mode setting
Indicates the scan mode setting status.
OFF : Asynchronous mode
ON : Synchronous mode
ON : Synchronous mode
1: Link special relay added to the function version B or later
2: Link special relay added to the AJ61QBT11 of hardware version F or later and the A1SJ61QBT11 of hardware version G or later