Mitsubishi Electronics FX3S-MT/DS ユーザーズマニュアル
41
FX
3S
Series Programmable Controllers
User's Manual - Hardware Edition
1
Introduc
tion
2
Features an
d
Par
t N
t N
am
es
3
Produc
t
Introducti
on
4
Sp
ec
ific
atio
ns
5
Ve
rsi
on and
Peri
pheral
pheral
De
vice
s
6
Sy
stem
Confi
gurati
on
7
In
st
alla
tio
n
8
Prep
ara
tion and
Pow
er Supply
Wi
ring
9
Input W
iri
ng
10
Hi
gh
-S
peed
Counters
5 Version Information and Peripheral Equipment Connectability
5.2 Programming Tool Applicability
5.1.2
Version check method
The PLC version number can be checked by reading the last three digits of device D8001/D8101.
5.1.3
Version upgrade history
FX
3S
Series performed the following upgrade.
5.2
Programming Tool Applicability
5.2.1
Applicable versions of programming tool
1. GX Works2
GX Works2 is applicable to FX
3S
PLCs from the following versions.
2. FX-30P
FX-30P is applicable to FX
3S
PLCs from the following version.
5.2.2
In the case of programming tool (version) not applicable
Inapplicable programming tools can be used by selecting an alternative PLC model.
1. Alternative model setting
*1.
"FX
2N
" is selected when the FX-10P(-E) is used.
2. Contents of restrictions
• Programming is enabled only in the function range such as instructions, device ranges and program sizes
available in both the FX
3S
PLC and the PLC selected as the alternative model.
• When the FX-10P(-E) is used, the function range such as instructions, device ranges and program sizes is
limited to that available in both the FX
3S
PLC and the FX
2N
PLC.
• Use a programming tool that can select either FX
3G
to change parameters, i.e. memory capacity, file
register capacity, etc.
• Memory capacity must be set to 4000 steps or less.
• Use a programming tool that can select the FX
• Use a programming tool that can select the FX
3G
model to program using the built-in USB port.
Version
Manufacturer's serial number
Contents of version upgrade
Ver. 1.00
133****
(March, 2013)
First product
Ver. 1.10
13X****
(October, 2013)
•
FX
3S
-30M/E-2AD (First product)
•
Supports connection of following expansion boards:
FX
FX
3G
-4EX-BD, FX
3G
-2EYT-BD
Ver. 1.20
14X****
(October, 2014)
•
Supports connection of display module (FX
3S
-5DM).
FX
3S
PLC version
Applicable GX Works2 version
Ver. 1.00
Ver. 1.492N or later
FX
3S
PLC version
Applicable FX-30P version
Ver. 1.00
Ver. 1.50 or later
Model to be programmed
Model to be set
Priority High
Low
FX
3S
PLC
FX3S
FX3G
FX1N
*1
FX2N
*1
D8001/D8101
PLC type and
version
2
8
1
0
0
Version information (Example: Ver. 1.00)
PLC type (Example: 28=FX
3S
PLC)