Mitsubishi Electronics IB-1500193(ENG)-D ユーザーズマニュアル

ページ / 528
MDS-D-SVJ3/SPJ3 Series Instruction Manual
2-2 Main circuit terminal block/control circuit connector
2 - 11
2-2-3 Main circuit connector (CNP1,CNP2,CNP3) wiring method
Use the supplied drive unit power supply connectors for wiring of CNP1, CNP2 and CNP3.
(1) MDS-D-SVJ3-03NA/04NA/07NA
MDS-D-SPJ3-075NA
(a) Drive unit power supply connectors
(b) Termination of the cables
Solid wire: After the sheath has been stripped, the cable can be used as it is.
Twisted wire: Use the cable after stripping the sheath and not twisting the core. At this time, take
                      care to avoid a short caused by the loose wires of the core and the adjacent pole.
                      Do not solder the core as it may cause a contact fault. Alternatively, a bar terminal
                      may be used to put the wires together.
For the wire size used for wring, refer to the section "5-1 selection of wire" in MDS-D-SVJ3/SPJ3 
Series Specifications Manual.
MDS-D-SPJ3-55NA/75NA/110NA does not have these connectors.
Cable size
Bar terminal type
Crimping tool
Manufacturer
[mm
2
]
AWG
For 1 cable
For 2 cables
1.25
16
BT1.25-9-1
-
NH1
NICHIFU
TUB-1.25
-
YHT-2210
Japan Solderless Terminal
1.5
16
AI1.5-8BK
AI-TWIN2×1.5-8BK
CRIMPFOX-UD6
Phoenix Contact
AI-TWIN2×1.5-12BK
2
14
BT2-9-1
-
NH1
NICHIFU
TUB-2
-
YHT-2210
Japan Solderless Terminal
 
POINT
CNP2
 
CNP1
 
CNP3
 
54928
0610(Molex)
54927
0510(Molex)
54928
0310(Molex)
Drive unit
Connector for CNP1
Connector for CNP2
Connector for CNP3
<Applicable cable example>
Cable finish OD:to Ǿ3.8mm
 
8 to 9mm
 
Core
 
Sheath