Avaya S8100 ユーザーズマニュアル
J Install and cable a CMC1 cabinet
Install an S8100 with a CMC1 system cabinet
348
S8100 Installation and Upgrades
November 2003
Install an S8100 with a CMC1 system cabinet
A CMC1 cabinet can be either floor- or wall-mounted. Set the Carrier Address ID installing each CMC1
cabinet.
cabinet.
Verify the carrier address ID on CMC1 cabinets
1
Verify and, if necessary, set the carrier address ID for each cabinet as shown in
page 349. Cabinet A is the processor cabinet and cabinets B, C, and D optional port carrier
cabinets (S8100 supports up to three cabinets, A, B, and C).
cabinets (S8100 supports up to three cabinets, A, B, and C).
on page 348 shows the settings for cabinets A, B, C, and D.
The 1s and Os indicate closed and open positions, respectively, of the 6 rocker switches on the
switch panel. For example, switches 2, 4, and 5 are in the closed position for cabinet A. This table
is embossed on the cabinet next the switch panel.
switch panel. For example, switches 2, 4, and 5 are in the closed position for cabinet A. This table
is embossed on the cabinet next the switch panel.
Table 60: Carrier address ID settings
A
B
C
D
6
O
O
O
O
5
l
O
O
l
4
l
l
O
O
3
O
l
O
O
2
l
O
O
O
1
O
l
l
l