JVC DLA-RS1 ユーザーズマニュアル

ページ / 50
6
42
Control of this unit via a computer is possible by connecting the computer to this unit with a RS-232C cross 
cable (D-Sub 9 pin)
.
The command between this unit and the computer consists of 
AHeaderB, AUnit IDB, ACommandB, ADataB and AEndB.
z
Header (1 byte), Unit ID (2 bytes), Command (2 bytes), Data (n bytes), End (1 byte)
„
Header
This binary code indicates the start of communication.
„
Unit ID
This code specifies the unit. The binary code is fixed at 
A8901B.
Pin No.
Signal
Operation
Signal Direction
2
Receive data
This unit
 PC
3
Transmit data
This unit
 PC
5
Signal ground
b
1, 4, 6 b  9
b
b
z
PC refers to the controller such as a personal computer.
Mode
Non-synchronous
Character Length
8 bit
Parity
None
Start Bit
1
Stop Bit
1
Data Rate
19200 bps
Data Format
Binary
Command Format
Binary code
Type
Description
21
Operating command
PC
 This unit
3F
Reference command
PC
 This unit
40
Response command
This unit
 PC
06
This unit
 PC
(When the command is accepted without error, it returns to PC)
This unit
Start Bit
Stop Bit
DLA-RS1_EN.book  Page 42  Wednesday, January 24, 2007  9:23 AM