Grizzly H8165 プリント

ページ / 1
Introduction
These  noise  reduction  kits  significantly  reduce 
the noise level of cyclone dust collectors without 
causing efficiency loss.
Installation Instructions
The mufflers are best installed in the outlet hose, 
as close to the filter as possible. The installation 
consists of removing a section of the outlet hose  
and  installing  the  muffler  in  its  place.  Wire  hose 
clamps are provided to secure the muffler to the 
outlet hose (see 
Figure 1).
To install the muffler:
1.  Measure  the  size  of  the  muffler  body  (see 
Figure 2).
2.  Using  a  felt-tip  marker,  mark  a  section  of 
the outlet hose equal in length to the muffler 
body. IMPORTANT: Leave at least 4" of out-
let hose between the filter and the muffler.
3.  Remove the portion of the outlet hose marked 
in 
Step 2.
4.  Fit the wire hose clamps over the ends of the 
outlet  hose  and  slide  them  back  at  least  2" 
from the opening.
5.  Apply the 3 x 15mm foam tape to the top and 
bottom rims of the muffler (see 
Figure 2).
6.  Fit  the  ends  of  the  outlet  hose  completely 
over the ends of the muffler.
7.  Slide the wire hose clamps down to the end 
of the hose near the body, then tighten them 
to secure the muffler in place.
MODEL H8165/66/67/68
NOISE REDUCTION KIT 
FOR CYCLONE DUST 
COLLECTORS
Muffler 
Body 
Foam
Tape
Foam
Tape
Figure 2. 
Size of muffler body.
If you need help installing the noise reducing kit, 
call our Tech Support at: (570) 546-9663.
COPyRIghT © NOveMbeR, 2006 by gRIzzLy INdUSTRIAL, INC.  RevISed NOveMbeR, 2009.
WaRNINg: NO pORTION OF THIS MaNUaL MaY bE REpRODUCED IN aNY SHapE
 OR FORM WITHOUT THE WRITTEN appROvaL OF gRIzzLY INDUSTRIaL, INC.
 #TR8803  PRINTed IN TAIWAN
Figure 1. 
Noise reducing kit installed.
Wire hose 
Clamp
Muffler
Wire hose 
Clamp