3. Configuration Using the Web Interface
3-2
 
Configuring ReachDSL Ports (8955)
Use the Configuration - DSL Port screen to set parameters for a DSL port on the 
8955 ReachDSL line card.
Procedure
To configure a ReachDSL port:
1. Select a Port from the drop-down list and click on Select. Current values for 
the port are displayed.
2. Enter or select the following fields:
3. Click on Apply.
Field
Description
Line Circuit Name
Enter a name from 1 to 255 characters long to indicate to 
whom the port is assigned. The following values are 
reserved and cannot be used: AVAILABLE (port is not 
assigned), and FAULTY (port is faulty and can not be 
assigned).
Line Code
The Line Code parameter currently has no effect on a 
ReachDSL card.
DSL Line Profile Name
Enter the name of a DSL line profile to set rates for the 
port.
DSL Alarm Profile Name
Enter the name of a DSL alarm profile to set alarm 
thresholds for the port.
Equivalent Working Length
Specify the estimated length of the DSL line. This used to 
limit transmit rates and maximum transmit power settings 
according to local spectrum management guidelines.
Max Tx Power
Specify the maximum transmit power setting for the 
ATU-C. The allowable Maximum Transmit Power range 
may be limited according to local spectrum management 
guidlines. The actual transmit power level will be based 
upon the symbol rate selected to maximize the transmit 
data rate and may be lower than the Maximum Transmit 
Power level configured.
Far End Max Tx Power
Specify the maximum transmit power setting for the 
ATU-R. The allowable Maximum Transmit Power range 
may be limited according to local spectrum management 
guidlines. The actual transmit power level will be based 
upon the symbol rate selected to maximize the transmit 
data rate and may be lower than the Maximum Transmit 
Power level configured.
Port Status
Select Enabled, Disabled, or Reset from the drop-down 
list to determine the status of the port.