2WIRE F-116P ユーザーズマニュアル

ページ / 150
Alignment and Troubleshooting
4-20
5. LSU Control
Item
Description
LD Power 
When “OK” key is pushed after ”ON” message displayed, ”OFF” message 
will be displayed after 10 seconds 
LSU Motor
If “OK” key is pushed after “ON” displayed, motor will be run. LSU motor 
will auto - stop after 10 seconds and ”OFF” message will be displayed.
LSU Ready
If “OK” key is pushed after “ON” displayed, motor will be run. ”1” message 
will be displayed.
Hsync
If “OK” key is pushed after “ON” displayed, motor will be run. ”1” message 
will be displayed.
6. DEV Control
Item
Description
THV (+)
If “OK” key is pushed after “ON” displayed, THV (+) will be turned on. 
THV (-)
If “OK” key is pushed after “ON” displayed, THV (-)  will be turned on. 
Dev Bias
If “OK” key is pushed after “ON” displayed, Dev Bias will be turned on.
MHV Bias
If “OK” key is pushed after “ON” displayed, MHV Bias will be turned on.
■  ACRONYMS 
• DEV   –  Developing High Voltage
• EDC   –  Embedded Diagnostic Control 
• F/W   –  Firmware
• HVPS –  High Voltage Power Supply
• H/W   –  Hardware
• LD   –  Laser Diode
• LSU   –  Laser Scanning Unit 
• MHV   –  Main High Voltage (Charge Voltage)
• OPC   –  Optical Photo Conductor
• SCF   –  Second Cassette Feeder
• THV   –  Transfer High Voltage