Golden Technologies LitewayTM ユーザーズマニュアル

ページ / 43
Diagnostics System
Any  fault  condition  of  the  controller  or  scooter  will  cause  the  “Power  on/diagnostics”  LED  to  flash.  
The LED light located on the faceplate of the scooter will tell you about the problem in how if flashes.
LED Flashes 1 time, pause, 1 time, and pause.  Battery needs recharging of bad connection with battery.
LED Flashes 2 times, pause, 2 times, pause.  Bad motor connection.  Check all connections between 
controller and motor.
LED Flashes 3 times, pause, 3 times, pause.  Short circuit between motor and battery connection. Contact 
authorized service facility.
LED Flashes 4 & 5 times.  (Not Used)
LED Flashes 6 times, pause, 6 times, pause.  Controller inhibited from operation.  Disconnect battery 
charger.
LED Flashes 7 times, pause, 7 times, pause.  Throttle fault.  Engager levers must be in neutral (centered) 
position before venicle is turned on.    Paddle fault and speed pot fault.  Switch vehicle off center levers 
and switch back on.
LED Flashes 8 times, pause, 8 times, pause.  Controller fault.  Check all connections.
LED Flashes 9 times, pause, 9 times, pause.  Bad parking brake connection.  Check parking brake and 
motor connections.
LED Flashes 10 times, pause, 10 times, pause.  Excessive voltage detected at controller.  Check battery 
connections.
Flashing LEDs.  Controller has entered Sleep mode.  Cycle Key Off/ On to reset.  
32
Golden Liteway GL-100 Owner’s Manual                                                                                                                                                           Revised 11/06