Connecting Power and Motors to the Controller
30
AX2500/2850 Motor Controller User’s Manual
 Version 1.7. February 1, 2005
Make sure that your motors have their wires isolated from the motor casing. Some 
motors, particularly automotive parts, use only one wire, with the other connected 
to the motor’s frame.
If you are using such a motor, make sure that it is mounted on isolators and that its 
casing will not cause a short circuit with other motors and circuits which may also 
be inadvertently connected to the same metal chassis.
Power Fuses
For low Amperage applications (below 30A per motor), it is recommended that a fuse be 
inserted in series with the main battery circuit as shown in the Figure 11 above. 
The fuse will be shared by the two output stages and therefore must be placed before the 
Y connection to the two power wires. 
Automotive fuses are generally slow and the following values are recommended depend-
ing on the desired level of protection. It should be noted that the current values listed will 
apply to the sum of the current drawn by each channel. Practically, a fuse will be of limited 
effectiveness. In very high current application (80A or more per channel), it will simply not 
be possible to find a fuse with the necessary Amps rating and speed needed to provide 
adequate protection. In such situation, the fuse may be just as well omitted keeping in 
mind that the controller’s current limiting circuit may not be able to protect it against short 
circuits and other abnormal situations. 
Important Warning
Fuses are typically slow to blow and will thus allow temporary excess current to flow 
through them for a time (the higher the excess current, the faster the fuse will blow). 
This characteristic is desirable in most cases, as it will allow motors to draw surges 
during acceleration and braking. However, it also means that the fuse may not be 
able to protect the controller.
Wire Length Limits
The AX2500/2850 regulates the output power by switching the power to the motors On 
and Off at high frequencies. At such frequencies, the wires’ inductance produces undesir-
able effects such as parasitic RF emissions, ringing and overvoltage peaks. The controller 
TABLE 5. Fuse selection table
Desired Current Protection (total for 
Channel 1 + Channel 2)
Fuse
120A
100A
100A
80A
80A
60A
60A
50A
50A
40A
40A
35A