RoboteQ AX2550/2850 ユーザーズマニュアル

ページ / 180
Serial (RS-232) Controls and Operation
96
AX2500/2850 Motor Controller User’s Manual
 Version 1.7. February 1, 2005
Reply:
nn
mm
oo
Where:
nn = Input E status
mm = Input F status
oo = Estop/Invert Switch Input status
Examples:
?I
Read Input status query
01
Controller replies, Input E is On
00
Input F is Off
01
Emergency stop switch is high (not triggered)
Note: the Input E value is not meaningful on the AX2850 or on the AX2550 with Encoder 
module and should be discarded.
Read and Modify Controller Settings
Description
These commands make it possible to examine and change the controller’s parameters 
stored in Flash. These commands will appear cryptic and difficult to use for manual param-
eter setting. It is recommended to use the Graphical configuration utility described in 
“Using the Roborun Configuration Utility” on page 159. Note that many parameters will 
not take effect until the controller is reset or a special command is sent (see “Apply Param-
eter Changes” on page 97). T
he complete list of parameters accessible using these com-
mands is listed in “RS232 Accessible Parameter Table” on page 99.
Read parameter
Syntax:
^mm
Reply:
DD
Where
mm= parameter number
DD= current parameter value
Example:
^00
Read value parameter 0
01
Controller replies, value is 01
Modify parameter
Syntax:
^mm nn
Reply:
+ if command was executed successfully
- if error
Where
mm= parameter number
nn= new parameter value
Examples:
^02 03
Store 03 into parameter 2