The range reference tables are given below.
(1) Reference table for offset/gain values of industrial shipment
settings (buffer memory addresses 202 to 233: Un\G202 to 233)
(a) For Q64AD
The reference values change depending on the setting of the pass data
classification setting (buffer memory address 200: Un\G200).
Address (Decimal)
CH1
CH2
CH3
CH4
Description
Pass data classification
setting
Reference value
(Hexadecimal)
Voltage specified
Approx. 800C
H
202
204
206
208
Industrial shipment settings offset value
Current specified
Approx. 800C
H
Voltage specified
Approx. FA64
H
203
205
207
209
Industrial shipment settings gain value
Current specified
Approx. BD38
H
(b) For Q68ADV
Address (Decimal)
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
Description
Reference value
(Hexadecimal)
202
204
206
208
210
212
214
216
Industrial shipment settings offset value
Approx. 800C
H
203
205
207
209
211
213
215
217
Industrial shipment settings gain value
Approx. FA64
H
(c) For Q68ADI
Address (Decimal)
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
Description
Reference value
(Hexadecimal)
202
204
206
208
210
212
214
216
Industrial shipment settings offset value
Approx. 800C
H
203
205
207
209
211
213
215
217
Industrial shipment settings gain value
Approx. BD38
H