Appendix 1.2 Combinations of A/D converter module functions and GX Configurator-AD
software versions
The following table indicates the A/D converter module functions and corresponding
GX Configurator-AD software versions.
Software version
Function
SW0D5C-QADU
-E 00A
SW0D5C-QADU
-E 10B
GX Configurator-
AD Version 1.10L
to 1.15R
GX Configurator-
AD Version 1.16S
or later
Normal resolution mode
High resolution mode 
1
High resolution mode status flag (X8) 
2
Maximum value/minimum value reset
completed flag (XD) 
2
Multiple PLC system compatibility 
1
Normal mode - offset/gain setting mode
switching
 
3
 : Compatible     : Not compatible
1   Functions added by function version B.
2   When the A/D converter module is function version A and the GX Configurator-AD software
version is SW0D5C-QDAU-E 20C or later or GX Configurator-AD Version 1.10L or later,
OFF is always displayed.
3   Functions added by function version C.
Appendix 1.3 Precautions for replacing the module of function version A with the one of
function version B or later
(1)   Incorporation into an existing system
You can use the wiring designed for function version A as-is to mount the A/D
converter module of function version B or later.
(2)   Program utilization
You can use the program created for function version A as-is with the  A/D
converter module of function version B or later.
(3)   Switch setting for intelligent function module
The setting of the offset/gain setting mode differs between function versions A
and B or later.
Perform the offset/gain settings after checking the RUN LED flashes in
offset/gain setting mode. If the RUN LED does not flash, check to see if the
switch 4 setting is correct.
(Refer to Section 4.5 for the intelligent function module switch setting of function
version B or later.)
<Contents of switch 4 setting for function version A>
H
00
H
            
 
: With temperature drift correction
01
to FF
H
 : Without temperature drift correction
00
H
            
 
: Normal mode (A/D conversion processing)
01
H
 to FF
H
 : Offset/gain setting mode 