Mitsubishi Electronics Q68ADI ユーザーズマニュアル

ページ / 140
3 - 18                                                                                                                                                       3 - 18
MELSEC-Q
3   SPECIFICATIONS
3.4.2 Buffer memory assignment (Q68ADV)
This section describes the assignment of the Q68ADV buffer memory.
Table 3.5 Buffer memory assignment (Q68ADV)
Address
Address
Hexadecimal
Decimal
Description
R/W
1
Hexadecimal
Decimal
Description
R/W
1
0
 H
0
A/D conversion enable/disable setting
R/W
2E
 H
46
1
 H
1
CH1 Average time/average number of times
R/W
to
to
System area
2
 H
2
CH2 Average time/average number of times
R/W
9D
 H
157
3
 H
3
CH3 Average time/average number of times
R/W
9E
 H
158
R/W
4
 H
4
CH4 Average time/average number of times
R/W
9F
 H
159
Mode switching setting
R/W
5
 H
5
CH5 Average time/average number of times
R/W
A0
 H
160
6
 H
6
CH6 Average time/average number of times
R/W
to
to
System area
7
 H
7
CH7 Average time/average number of times
R/W
C9
 H
201
8
 H
8
CH8 Average time/average number of times
R/W
CA
 H
202
CH1 Industrial shipment settings offset value
2
R/W
9
 H
9
Averaging process setting
R/W
CB
 H
203
CH1 Industrial shipment settings gain value
2
R/W
A
 H
10
A/D conversion completed flag
R
CC
 H
204
CH2 Industrial shipment settings offset value
2
R/W
B
 H
11
CH1 Digital output value
R
CD
 H
205
CH2 Industrial shipment settings gain value
2
R/W
C
 H
12
CH2 Digital output value
R
CE
 H
206
CH3 Industrial shipment settings offset value
2
R/W
D
 H
13
CH3 Digital output value
R
CF
 H
207
CH3 Industrial shipment settings gain value
2
R/W
E
 H
14
CH4 Digital output value
R
D0
 H
208
CH4 Industrial shipment settings offset value
2
R/W
F
 H
15
CH5 Digital output value
R
D1
 H
209
CH4 Industrial shipment settings gain value
2
R/W
10
 H
16
CH6 Digital output value
R
D2
 H
210
CH5 Industrial shipment settings offset value
2
R/W
11
 H
17
CH7 Digital output value
R
D3
 H
211
CH5 Industrial shipment settings gain value
2
R/W
12
 H
18
CH8 Digital output value
R
D4
 H
212
CH6 Industrial shipment settings offset value
2
R/W
13
 H
19
Error code
R
D5
 H
213
CH6 Industrial shipment settings gain value
2
R/W
14
 H
20
Setting range (CH1 to CH4)
R
D6
 H
214
CH7 Industrial shipment settings offset value
2
R/W
15
 H
21
Setting range (CH5 to CH8)
R
D7
 H
215
CH7 Industrial shipment settings gain value
2
R/W
16
 H
22
Offset/gain setting mode Offset specification
R/W
D8
 H
216
CH8 Industrial shipment settings offset value
2
R/W
17
 H
23
Offset/gain setting mode Gain specification
R/W
D9
 H
217
CH8 Industrial shipment settings gain value
2
R/W
18
 H
24
DA
 H
218
CH1 User range settings offset value
2
R/W
to
to
System area
DB
 H
219
CH1 User range settings gain value
2
R/W
1D
 H
29
DC
 H
220
CH2 User range settings offset value
2
R/W
1E
 H
30
CH1 Maximum value
R/W
DD
 H
221
CH2 User range settings gain value
2
R/W
1F
 H
31
CH1 Minimum value
R/W
DE
 H
222
CH3 User range settings offset value
2
R/W
20
 H
32
CH2 Maximum value
R/W
DF
 H
223
CH3 User range settings gain value
2
R/W
21
 H
33
CH2 Minimum value
R/W
E0
 H
224
CH4 User range settings offset value
2
R/W
22
 H
34
CH3 Maximum value
R/W
E1
 H
225
CH4 User range settings gain value
2
R/W
23
 H
35
CH3 Minimum value
R/W
E2
 H
226
CH5 User range settings offset value
2
R/W
24
 H
36
CH4 Maximum value
R/W
E3
 H
227
CH5 User range settings gain value
2
R/W
25
 H
37
CH4 Minimum value
R/W
E4
 H
228
CH6 User range settings offset value
2
R/W
26
 H
38
CH5 Maximum value
R/W
E5
 H
229
CH6 User range settings gain value
2
R/W
27
 H
39
CH5 Minimum value
R/W
E6
 H
230
CH7 User range settings offset value
2
R/W
28
 H
40
CH6 Maximum value
R/W
E7
 H
231
CH7 User range settings gain value
2
R/W
29
 H
41
CH6 Minimum value
R/W
E8
 H
232
CH8 User range settings offset value
2
R/W
2A
 H
42
CH7 Maximum value
R/W
E9
 H
233
CH8 User range settings gain value
2
R/W
2B
 H
43
CH7 Minimum value
R/W
2C
 H
44
CH8 Maximum value
R/W
2D
 H
45
CH8 Minimum value
R/W
1  Indicates whether reading and writing to/from a sequence program are enabled.
R  : Read enabled
W : Write enabled
2  Areas used to restore the user range settings offset/gain values when online
module change is made.
Refer to chapter 7 for details of online module change.