Cobalt Networks 9034 ユーザーズマニュアル

ページ / 28
Page 18 of 28 
9034 Owner’s Manual  
••••  (V 2.0) 
Restore Factory Settings 
In this parameter, move the toggle switch up to make the factory default settings active, and make the 
stored settings equal to the factory settings. 
Information Submenu 
Menu Structure 
Parameter Type 
Info 
+POW 
Positive Watts Consumed 
 
-POW 
Negative Watts Consumed 
 
SWR# 
Software Release Number 
 
SWB# 
Software Build Number 
Positive Watts Consumed 
A read only indication of power consumed by the card from the frames +12V rail. 
Negative Watts Consumed 
A read only indication of power consumed by the card from the frames +-7.5V rail. 
Software Release Number 
A read only indication of the software release number. A higher number is newer release of software. 
Software Build Number 
A read only indication of the software build number. Software build number is an internal indicator 
used by Cobalt engineers to differentiate different software builds. 
 
 
 
Factory Default Settings 
The factory default settings are as follows 
1)  The proc module is enabled, but all parameters are set to unity. 
2)  The audio mapping is for AES Inputs to AES Outputs. 
3)  Audio gain is set to 0dB and polarity is set to normal on all channels. 
4)  The Frame Sync is disabled, reference 1 or 2 must be chosen to enable the frame sync.