ユーザーズマニュアル目次Contents3Before You Begin91.1 Overview91.2 Safety91.3 Determining transmitter information91.4 DeviceNet functionality101.5 Determining version information101.6 Communication tools101.7 Planning the configuration111.8 Pre-configuration worksheet121.9 Flowmeter documentation131.10 Micro Motion customer service14Flowmeter Startup152.1 Overview152.2 Setting the DeviceNet node address and baud rate152.3 Bringing the transmitter online15Using the Transmitter User Interface173.1 Overview173.2 User interface without or with display173.3 Removing and replacing the transmitter housing cover193.4 Using the optical switches193.5 Using the display203.5.1 Display language203.5.2 Viewing process variables203.5.3 Using display menus213.5.4 Display password223.5.5 Entering floating-point values with the display22Connecting with ProLink II or Pocket ProLink Software254.1 Overview254.2 Requirements254.3 Configuration upload/download254.4 Connecting to a Model 2400S DN transmitter264.4.1 Connection options264.4.2 Service port connection parameters264.4.3 Connecting via the service port clips264.4.4 Connecting via the IrDA port284.5 ProLink II language28Using a DeviceNet Tool295.1 Overview295.2 Connecting to the Model 2400S DN transmitter295.3 Using the DeviceNet device profile295.4 Using a DeviceNet tool305.4.1 Type A tools305.4.2 Type B tools305.5 Default assemblies31Required Transmitter Configuration336.1 Overview336.2 Characterizing the flowmeter336.2.1 When to characterize336.2.2 Characterization parameters336.2.3 How to characterize356.3 Configuring the measurement units366.3.1 Mass flow units386.3.2 Volume flow units386.3.3 Density units406.3.4 Temperature units416.3.5 Pressure units41Using the Transmitter437.1 Overview437.2 Recording process variables437.3 Viewing process variables447.3.1 With the display447.3.2 With ProLink II447.3.3 With a DeviceNet tool457.4 Using the LEDs497.4.1 Using the module LED497.4.2 Using the network LED507.5 Viewing transmitter status507.5.1 Using the status LED507.5.2 Using ProLink II517.5.3 Using a DeviceNet tool517.6 Handling status alarms517.6.1 Using the display527.6.2 Using ProLink II537.6.3 Using a DeviceNet tool547.7 Using the totalizers and inventories557.7.1 Viewing current values for totalizers and inventories567.7.2 Controlling totalizers and inventories57Optional Configuration638.1 Overview638.2 Configuring volume flow measurement for gas648.2.1 Using ProLink II658.2.2 Using a DeviceNet tool668.3 Configuring cutoffs668.3.1 Cutoffs and volume flow678.4 Configuring the damping values678.4.1 Damping and volume measurement688.5 Configuring the flow direction parameter688.6 Configuring events698.6.1 Defining events698.6.2 Checking and reporting event status728.6.3 Changing event setpoints from the display728.7 Configuring slug flow limits and duration728.8 Configuring status alarm severity738.9 Configuring the display758.9.1 Update period758.9.2 Language758.9.3 Enabling and disabling display functions758.9.4 Configuring the LCD backlight768.9.5 Configuring the display variables and display precision778.10 Configuring digital communications788.10.1 DeviceNet node address788.10.2 DeviceNet baud rate798.10.3 DeviceNet configurable input assembly798.10.4 Modbus address808.10.5 Modbus ASCII support808.10.6 IrDA port usage818.10.7 Digital communications fault action818.10.8 Fault timeout828.11 Configuring device settings828.12 Configuring sensor parameters838.13 Configuring the petroleum measurement application838.13.1 About the petroleum measurement application838.13.2 Configuration procedure858.14 Configuring the enhanced density application868.14.1 About the enhanced density application868.14.2 Configuration procedure88Pressure Compensation and Temperature Compensation919.1 Overview919.2 Pressure compensation919.2.1 Options919.2.2 Pressure correction factors929.2.3 Configuration929.3 External temperature compensation939.4 Obtaining external pressure and temperature data95Measurement Performance9710.1 Overview9710.2 Meter validation, meter verification, and calibration9710.2.1 Meter verification9810.2.2 Meter validation and meter factors9810.2.3 Calibration9810.2.4 Comparison and recommendations9910.3 Performing meter verification9910.3.1 Uncertainty limit and test results10410.3.2 Additional ProLink II tools for meter verification10510.4 Performing meter validation10510.5 Performing zero calibration10710.5.1 Preparing for zero10810.5.2 Zero procedure10810.6 Performing density calibration11110.6.1 Preparing for density calibration11210.6.2 Density calibration procedures11210.7 Performing temperature calibration117Troubleshooting11911.1 Overview11911.2 Guide to troubleshooting topics11911.3 Micro Motion customer service12011.4 Transmitter does not operate12011.5 Transmitter does not communicate12011.6 Checking the communication device12111.7 Diagnosing wiring problems12111.7.1 Checking the DeviceNet cable and connector12111.7.2 Checking grounding12211.8 Zero or calibration failure12211.9 Fault conditions12211.10 Simulation mode for process variables12211.11 Transmitter LEDs12311.12 Status alarms12411.13 Checking process variables12711.14 Checking slug flow12911.15 Checking the sensor tubes13011.16 Checking the flow measurement configuration13011.17 Checking the characterization13011.18 Checking the calibration13011.19 Checking the test points13011.19.1 Obtaining the test point values13111.19.2 Evaluating the test points13111.19.3 Drive gain problems13211.19.4 Low pickoff voltage13211.20 Checking sensor circuitry133Default Values and Ranges139A.1 Overview139A.2 Most frequently used defaults and ranges139Menu Flowcharts143B.1 Overview143B.2 Version information143Device Profile151C.1 Overview151C.2 Analog Input Point Object (0x0A)152C.3 Gas Standard Volume Object (0x64)154C.4 Calibration Object (0x65)155C.5 Diagnostics Object (0x66)157C.6 Sensor Information Object (0x67)167C.7 Local Display Object (0x68)168C.8 API Object (0x69)170C.9 Enhanced Density Object (0x6A)171C.10 Totalizer and inventory measurement unit codes173C.11 Process variable codes174C.12 Alarm index codes175Display Codes and Abbreviations177D.1 Overview177D.2 Codes and abbreviations177Index181サイズ: 2.54MBページ数: 188Language: Englishマニュアルを開く