ユーザーズマニュアル (BB5000XALR)目次Introduction12Chapter Outline12Server Board Use Disclaimer12Product Overview13Intel® Server Board S5000PAL / S5000XAL Feature Set13Server Board Layout14Connector and Component Locations15Figure 1. Components & Connector Location Diagram16Light Guided Diagnostic LED Locations17Figure 2. Light Guided Diagnostic LED Location Diagram17External I/O Connector Locations18Figure 3. Intel® Server Board S5000PAL / S5000XAL ATX I/O Layout18Server Board Mechanical Drawings19Figure 6. Intel® Server Board S5000PAL / S5000XAL – Restricted Areas on Side 121Figure 7. Intel® Server Board S5000PAL / S5000XAL – Restricted Areas on Side 222Functional Architecture24Figure 9. Server Board Functional Block Diagram24Intel® 5000P and 5000X Memory Controller Hubs (MCH)25System Bus Interface25Processor Support25Memory Sub-system26Figure 10. CEK Processor Mounting26Figure 11. Memory Layout27Table 1. I2C Addresses for Memory Module SMB27Table 2. Maximum 8 DIMM System Memory Configuration – x8 Single Rank28Table 3. Maximum 8 DIMM System Memory Configuration – x4 Dual Rank28Figure 12. Recommended Minimum Two DIMM Memory Configuration29Figure 13. Recommended Four DIMM Configuration30Figure 14. Single Branch Mode Sparing DIMM Configuration31Snoop Filter (5000X MCH only)32ESB-2 IO Controller32PCI Sub-system33Table 4. PCI Bus Segment Characteristics33Serial ATA Support35Parallel ATA (PATA) Support36USB 2.0 Support36Video Support36Table 5. Video Modes37Network Interface Controller (NIC)38Intel® I/O Acceleration Technology38MAC Address Definition38Table 6. NIC2 Status LED38Super I/O39Table 7. Serial A Header Pin-out39Figure 15. Serial Port Configuration Jumper Location40Table 8. Rear Serial B Port Adapter Pin-out40Platform Management42Figure 16. SMBUS Block Diagram42Connector / Header Locations and Pin-outs43Board Connector Information43Table 9. Board Connector Matrix43Power Connectors44Table 10. Power Connector Pin-out (J3K3)44Table 11. 12V Power Connector Pin-out (J3K4)44Table 12. Power Supply Signal Connector Pin-out (J1K1)44System Management Headers45Intel® Remote Management Module (RMM) Connector45Table 13. Intel® RMM Connector Pin-out (J1C5)45Intel® RMM NIC Connector46Table 14. 30-pin Intel® RMM NIC Module Connector Pin-out (J1B2)46LCP/AUX IPMB Header47IPMB Header47Riser Card Slots47Table 15. LPC/AUX IPMB Header Pin-out (J1C2)47Table 16. IPMB Header Pin-out (J1C3)47Table 17. Low-profile Riser Slot Pin-out (J5B1)47Table 18. Full-height Riser Slot Pin-out (J4F1)48SSI Control Panel Connector52Bridge Board Connector52Table 19. Front Panel SSI Standard 24-pin Connector Pin-out (J3H2)52Table 20. 120-pin Bridgeboard Connector Pin-out (J4G1)52I/O Connector Pin-out Definition54VGA Connector54NIC Connectors54Table 21. VGA Connector Pin-out (J6A1)54Table 22. RJ-45 10/100/1000 NIC Connector Pin-out (JA8A1, JA8A2)54IDE Connector55Intel® I/O Expansion Module Connector55Table 23. 44-pin IDE Connector Pin-out (J3G1)55SATA Connectors56Table 24. 50-pin Intel® I/O Expansion Module Connector Pin-out (J3B1)56Table 25. SATA Connector Pin-out (J1H1, J1G2, J1G1, J1F2, J1E3)56Serial Port Connectors57Keyboard and Mouse Connector57Table 26. External RJ-45 Serial ‘B’ Port Pin-out (J9A2)57Table 27. Internal 9-pin Serial ‘A’ Header Pin-out (J1B1)57Table 28. Stacked PS/2 Keyboard and Mouse Port Pin-out (J9A1)57USB 2.0 Connectors58Table 29. External USB Connector Pin-out (J5A1, J6A2)58Table 30. Internal USB Connector Pin-out (J1J1)58Fan Headers59Table 31. SSI Fan Connector Pin-out (J9K1,J5K1,J3K1,J3K2,J7A2,J7A1)59Jumper Block Settings60Recovery Jumper Blocks60Figure 17. Recovery Jumper Blocks (J1D1, J1D2, J1D3)60Table 32. Recovery Jumpers (J1D1, J1D2, J1D3)60CMOS Clear and Password Reset Usage Procedure61BMC Force Update Procedure61BIOS Select Jumper62Figure 18. BIOS Select Jumper (J3H1)62External RJ45 Serial Port Jumper Block63Figure 19. External RJ45 Serial Port Configuration Jumper63Light Guided Diagnostics645-Volt Standby LED64Figure 20. 5V Standby Status LED Location64System ID LED and System Status LED65Figure 21. System ID LED and System Status LED Locations65System Status LED – BMC Initialization66DIMM Fault LEDs67Processor Fault LED67Figure 22. DIMM Fault LED Locations67Figure 23. Processor Fault LED Location67Post Code Diagnostic LEDs68Figure 24. POST Code Diagnostic LED Location68Power and Environmental Specifications69Intel® Server Board S5000PAL / S5000XAL Design Specifications69Table 33: Server Board Design Specifications69Server Board Power Requirements70Processor Power Support70Figure 25. Power Distribution Block Diagram70Power Supply Output Requirements71Turn On No Load Operation71Table 35. 600W Load Ratings71Table 36: No load operating range71Grounding72Standby Outputs72Remote Sense72Voltage Regulation72Table 37. Voltage Regulation Limits72Dynamic Loading73Capacitive Loading73Closed-Loop Stability73Common Mode Noise73Table 38. Transient Load Requirements73Table 39. Capacitive Loading Conditions73Ripple / Noise74Soft Starting74Timing Requirements74Table 40. Ripple and Noise74Figure 26. Output Voltage Timing75Table 41. Output Voltage Timing75Figure 27. Turn On/Off Timing (Power Supply Signals)76Table 42. Turn On/Off Timing76Residual Voltage Immunity in Standby Mode77Regulatory and Certification Information78Product Regulatory Compliance78Product Safety & Electromagnetic (EMC) Compliance78Electromagnetic Compatibility Notices79FCC Verification Statement (USA)79ICES-003 (Canada)79Europe (CE Declaration of Conformity)79BSMI (Taiwan)80RRL (Korea)80Product Ecology Compliance81Other Markings82Appendix A: Integration and Usage Tips83Appendix B: BMC Sensor Tables84Table 43. BMC Sensors86Appendix C: POST Code Diagnostic LED Decoder100Figure 28. Diagnostic LED Placement Diagram100Table 44: POST Progress Code LED Example100Table 45. Diagnostic LED POST Code Decoder101Appendix D: POST Error Messages and Handling104Table 46. POST Error Messages and Handling104Table 47. POST Error Beep Codes106Table 48. BMC Beep Codes106Appendix E: Supported Intel® Server Chassis107Figure 29. 1U – Intel® Server Chassis SR1500 Overview107Figure 30. 1U – Intel® Server Chassis SR1550 Overview108Figure 31. 2U – Intel® Server Chassis SR2500 Overview109Glossary110Reference Documents113サイズ: 2.84MBページ数: 112Language: Englishマニュアルを開く
ユーザーズマニュアル目次Introduction12Chapter Outline12Server Board Use Disclaimer12Product Overview13Intel® Server Board S5000PAL / S5000XAL Feature Set13Server Board Layout14Connector and Component Locations15Light Guided Diagnostic LED Locations17External I/O Connector Locations18Server Board Mechanical Drawings19Functional Architecture24Intel® 5000P and 5000X Memory Controller Hubs (MCH)25System Bus Interface25Processor Support25Memory Sub-system27Snoop Filter (5000X MCH only)33ESB-2 IO Controller33PCI Sub-system34Serial ATA Support36Parallel ATA (PATA) Support37USB 2.0 Support37Video Support37Network Interface Controller (NIC)39Intel® I/O Acceleration Technology39MAC Address Definition39Super I/O40Platform Management43Connector / Header Locations and Pin-outs44Board Connector Information44Power Connectors45System Management Headers46Intel® Remote Management Module (RMM) Connector46Intel® RMM NIC Connector47LCP/AUX IPMB Header48IPMB Header48Riser Card Slots48SSI Control Panel Connector53Bridge Board Connector53I/O Connector Pin-out Definition55VGA Connector55NIC Connectors55IDE Connector56Intel® I/O Expansion Module Connector56SATA Connectors57Serial Port Connectors58Keyboard and Mouse Connector58USB 2.0 Connectors59Fan Headers60Jumper Block Settings61Recovery Jumper Blocks61CMOS Clear and Password Reset Usage Procedure62BMC Force Update Procedure62BIOS Select Jumper63External RJ45 Serial Port Jumper Block64Light Guided Diagnostics655-Volt Standby LED65System ID LED and System Status LED66System Status LED – BMC Initialization67DIMM Fault LEDs68Processor Fault LED68Post Code Diagnostic LEDs69Power and Environmental Specifications70Intel® Server Board S5000PAL / S5000XAL Design Specifications70Server Board Power Requirements71Processor Power Support71Power Supply Output Requirements72Turn On No Load Operation72Grounding73Standby Outputs73Remote Sense73Voltage Regulation73Dynamic Loading74Capacitive Loading74Closed-Loop Stability74Common Mode Noise74Ripple / Noise75Soft Starting75Timing Requirements75Residual Voltage Immunity in Standby Mode78Regulatory and Certification Information79Product Regulatory Compliance79Product Safety & Electromagnetic (EMC) Compliance79Electromagnetic Compatibility Notices80FCC Verification Statement (USA)80ICES-003 (Canada)80Europe (CE Declaration of Conformity)80BSMI (Taiwan)81RRL (Korea)81Product Ecology Compliance82Other Markings83Appendix A: Integration and Usage Tips84Appendix B: BMC Sensor Tables85Appendix C: POST Code Diagnostic LED Decoder101Appendix D: POST Error Messages and Handling105Appendix E: Supported Intel® Server Chassis108Glossary111Reference Documents114Figure 1. Components & Connector Location Diagram16Figure 2. Light Guided Diagnostic LED Location Diagram17Figure 3. Intel® Server Board S5000PAL / S5000XAL ATX I/O Layout18Figure 6. Intel® Server Board S5000PAL / S5000XAL – Restricted Areas on Side 121Figure 7. Intel® Server Board S5000PAL / S5000XAL – Restricted Areas on Side 222Figure 9. Server Board Functional Block Diagram24Figure 10. CEK Processor Mounting27Figure 11. Memory Layout27Figure 12. Recommended Minimum Two DIMM Memory Configuration30Figure 13. Recommended Four DIMM Configuration31Figure 14. Single Branch Mode Sparing DIMM Configuration32Figure 15. Serial Port Configuration Jumper Location41Figure 16. SMBUS Block Diagram43Figure 17. Recovery Jumper Blocks (J1D1, J1D2, J1D3)61Figure 18. BIOS Select Jumper (J3H1)63Figure 19. External RJ45 Serial Port Configuration Jumper64Figure 20. 5V Standby Status LED Location65Figure 21. System ID LED and System Status LED Locations66Figure 22. DIMM Fault LED Locations68Figure 23. Processor Fault LED Location68Figure 24. POST Code Diagnostic LED Location69Figure 25. Power Distribution Block Diagram71Figure 26. Output Voltage Timing76Figure 27. Turn On/Off Timing (Power Supply Signals)77Figure 28. Diagnostic LED Placement Diagram101Figure 29. 1U – Intel® Server Chassis SR1500 Overview108Figure 30. 1U – Intel® Server Chassis SR1550 Overview109Figure 31. 2U – Intel® Server Chassis SR2500 Overview110Table 1. Processor Support Matrix26Table 2. I2C Addresses for Memory Module SMB28Table 3. Maximum 8 DIMM System Memory Configuration – x8 Single Rank28Table 4. Maximum 8 DIMM System Memory Configuration – x4 Dual Rank28Table 5. PCI Bus Segment Characteristics34Table 6. Video Modes38Table 7. NIC2 Status LED39Table 8. Serial A Header Pin-out40Table 9. Rear Serial B Port Adapter Pin-out41Table 10. Board Connector Matrix44Table 11. Power Connector Pin-out (J3K3)45Table 12. 12V Power Connector Pin-out (J3K4)45Table 13. Power Supply Signal Connector Pin-out (J1K1)45Table 14. Intel® RMM Connector Pin-out (J1C5)46Table 15. 30-pin Intel® RMM NIC Module Connector Pin-out (J1B2)47Table 16. LPC/AUX IPMB Header Pin-out (J1C2)48Table 17. IPMB Header Pin-out (J1C3)48Table 18. Low-profile Riser Slot Pin-out (J5B1)48Table 19. Full-height Riser Slot Pin-out (J4F1)49Table 20. Front Panel SSI Standard 24-pin Connector Pin-out (J3H2)53Table 21. 120-pin Bridgeboard Connector Pin-out (J4G1)53Table 22. VGA Connector Pin-out (J6A1)55Table 23. RJ-45 10/100/1000 NIC Connector Pin-out (JA8A1, JA8A2)55Table 24. 44-pin IDE Connector Pin-out (J3G1)56Table 25. 50-pin Intel® I/O Expansion Module Connector Pin-out (J3B1)57Table 26. SATA Connector Pin-out (J1H1, J1G2, J1G1, J1F2, J1E3)57Table 27. External RJ-45 Serial ‘B’ Port Pin-out (J9A2)58Table 28. Internal 9-pin Serial ‘A’ Header Pin-out (J1B1)58Table 29. Stacked PS/2 Keyboard and Mouse Port Pin-out (J9A1)58Table 30. External USB Connector Pin-out (J5A1, J6A2)59Table 31. Internal USB Connector Pin-out (J1J1)59Table 32. SSI Fan Connector Pin-out (J9K1,J5K1,J3K1,J3K2,J7A2,J7A1)60Table 33. Recovery Jumpers (J1D1, J1D2, J1D3)61Table 34: Server Board Design Specifications70Table 36. 600W Load Ratings72Table 37: No load operating range72Table 38. Voltage Regulation Limits73Table 39. Transient Load Requirements74Table 40. Capacitive Loading Conditions74Table 41. Ripple and Noise75Table 42. Output Voltage Timing76Table 43. Turn On/Off Timing77Table 44. BMC Sensors87Table 45: POST Progress Code LED Example101Table 46. Diagnostic LED POST Code Decoder102Table 47. POST Error Messages and Handling105Table 48. POST Error Beep Codes107Table 49. BMC Beep Codes107サイズ: 2.85MBページ数: 113Language: Englishマニュアルを開く