ユーザーズマニュアル目次Task List5Contents9Regulatory information17North American regulatory information17Canadian Notice17Federal Communications Commission (FCC) Notice18Ringer Equivalence Number (REN)18EMI/EMC (FCC Part 15)18Important safety instructions19Safety20Enhanced 911 configuration21Radio-frequency interference21Telecommunication registration21International regulatory information22Safety23Additional safety information23ITU standardization compliance24Getting started25About this guide25Audience25Acronyms25Symbols and conventions used in this guide27Related publications29How to get help30Introducing the BCM hardware31Main units31BCM200 main unit32BCM400 main unit34BCM400 advanced function tray37BCM400 advanced function tray RAID status LEDs38Base function tray component hardware39Base function tray faceplate components39Base function tray internal components40Main card43Data networking components46I/O interface card48BCM expansion unit (BCM400 only)49MBM bays and backplane50Media bay modules (MBMs)51Trunk media bay modules (MBMs)53Station media bay modules (MBMs)56Specialized media bay modules (MBMs)61BCM400 expansion gateway62BCM components63BCM power supply63BCM400 redundant power supply64Power supply adapter cord (international users)66Uninterruptable power supply66Hard disk66RAID upgrade kit67Cooling fan68Field replaceable units (FRU)69Telephones and adapters72Viewing the BCM system LEDs77Base function tray system status display LEDs77Media bay module LEDs79DTM LEDs80BRIM LEDs82Installation overview83Checking the installation prerequisites87General requirements87Environmental requirements87Electrical requirements88Site telephony wiring requirements88Digital loop88Analog loop89System equipment, supplies, and tools89Basic hardware89Optional equipment89Other hardware and tools90Installing the BCM main unit91Unpacking the main unit92Installing the main unit in an equipment rack92Installing the main unit on the wall96Installing the main unit on a flat surface98Installing an expansion unit101Unpacking the expansion unit102Installing the expansion unit102Connecting the BCM expansion unit to the BCM main unit103Installing a media bay module (MBM)105Selecting MBMs for your BCM system105Selecting trunk MBMs106Selecting station MBMs108Selecting a fiber expansion module (FEM)109Determining system capacity109Understanding DS30 numbers109Setting offsets110Determining bus requirements111Assigning DS30 resources114Choosing the assigned order for MBMs115Determining MBM DIP switch settings116Setting MBM DIP switches120Assigning line and extension numbers121DTM switch settings121DDIM switch settings122BRI switch settings123CTM switch settings123GATM switch settings1254x16 switch settings126ASM 8 and GASM8 switch settings128DSM switch settings130FEM switch settings133BCM400 expansion gateway MBMs134Installing an MBM135Connecting the cables137Connecting power to the BCM system138Checking system power and status139Wiring the MBMs140Connect the MBMs to service providers142Wiring MBMs to internal connections144Wiring the FEM148Setting DNs and port numbers149MBM combinations150Combining CTMs/GATMs and 4x16s151Fully-loaded setup151DECT combinations153Changing configurations154System setup155Connecting the data networking hardware155Connecting the cards156Installing the cards159Installing telephones and peripherals161System telephones161Analog terminal adapter 2161Central Answering Position (CAP/eCAP)162Telephone port and DN cross-reference162Installing an emergency telephone165Installing IP Phones165Installing the mobility systems165Installing T7406 cordless systems165Moving telephones166Installing the analog terminal adapter167Configuration overview167Analog telephone167Analog data device168Installing the ATA2168Connecting the ATA2168Mounting the ATA2169Test insertion loss measurement170Configuring the ATA2172Installing optional telephony equipment173Installing an auxiliary ringer173Activating auxiliary ringer programming174Connecting the external paging system174Connecting an external music source175Music-on-hold specifications175Initializing the system177Data parameter requirements177Using the default BCM system IP address177Using the Ethernet crossover cable178Setting the crossover connections178Connecting through Ethernet crossover cable178Connecting through the serial port179Null modem cable setup180Software keycode181Regenerating a keycode after system replacement182Configuring the BCM system183Initial parameters overview184Startup parameters overview185Using Telset Administration to set the basic parameters187Configuring the initial parameters188Using Element Manager to set the basic parameters193Prerequisites194Accessing the BCM system194Configuring the initial parameters195Configuring the startup parameters198Using the Startup Profile to configure parameters205Startup Profile requirements206Configuring basic parameters207Startup Profile times and LED sequence209Completing the initial installation (optional)211Configuring the media bay module212Configuring modem settings213Checking for software updates213Configuring voice mail213Customizing security policies213Performing a backup214System monitoring and troubleshooting215System status display LEDs216Monitoring media bay module LEDs217Monitoring standard configuration hard disk status using Element Manager218Monitoring the RAID LEDs219RAID disk mirroring221Monitoring or configuring disk mirror settings using Element Manager222Accessing disk mirroring through Element Manager222Monitoring RAID disk mirror operational status using Element Manager224Accessing the RAID status report using Element Manager225Monitoring disk mirroring using Element Manager225BCM system does not function226Emergency telephone does not function226ATA2 does not function227Preparing hardware for maintenance or upgrades229Precautions229Special tools231Performing a system shutdown231Restarting the system after maintenance232Base function tray maintenance procedures233Removing the base function tray234Advanced function tray maintenance procedures239Removing and installing the main unit top cover244Removing the main unit top cover244Installing the main unit top cover246Using the backup and restore utility248Replacing a media bay module249Removing an MBM250Installing an MBM252Returning the system to operation252Replacing the hard disk253Installing a RAID system255Replacing a RAID configuration hard disk257Removing a hard disk cage258Removing a hard disk cage from a BCM200 main unit258Removing a hard disk cage from a BCM400 advanced function tray260Installing a hard disk cage261Installing a hard disk cage in a BCM200 main unit262Installing a hard disk cage in a BCM400 main unit263Replacing a hard disk in the hard disk cage265Removing a hard disk from a standard configuration hard disk cage265Removing a primary hard disk from a RAID hard disk cage266Removing a mirror hard disk from a RAID hard disk cage267Installing a hard disk into a standard configuration hard disk cage268Installing a primary hard disk into a RAID hard disk cage269Installing a mirror hard disk into a RAID hard disk cage271Initializing the hard disk in a single-disk configuration273Initializing the hard disk in a RAID configuration273Replacing or upgrading a power supply275Replacing a standard power supply275Removing a BCM200 power supply276Installing a BCM200 standard power supply278Removing a BCM400 standard power supply282Installing a BCM400 standard power supply284Upgrading to a redundant power supply286Removing the PSU status connector jumper287Installing a redundant power supply cage (BCM400 only)288Removing a BCM400 redundant power supply cage293Installing a power supply module295Removing a power supply module297Replacing data cards and processing hardware299Replacing cards299Installing the WAN card302Installing the modem card309Replacing the processor expansion card (PEC)311Installing a processor expansion card (PEC)314Replacing memory315Increasing the amount of memory316Removing the dual in-line memory module (DIMM) card316Replacing the clock/calendar battery318Replacing or installing a cooling fan323Replacing a cooling fan323Removing a BCM400 cooling fan324Installing a BCM400 cooling fan326Removing a BCM200 cooling fan329Installing the BCM200 cooling fan331Removing an expansion unit fan332Installing an expansion unit fan334Troubleshooting cooling fans334DTM wiring chart335BRIM wiring chart337GATM wiring chart3394x16 wiring charts343DSM16 and DSM32 wiring charts347ASM8, ASM8+, and GASM8 wiring chart349Market profile attributes351Media bay module availability351FEM MBM-Norstar trunk cartridge combinations352Time zones and language information353Time and date format based on language353Language support for South America and Central America354Caller ID display formats355Core parameters for market profiles355Global analog trunk parameters368GASM8 parameters371ISDN line services374Analog and digital trunk types375Index377サイズ: 9.92MBページ数: 382Language: Englishマニュアルを開く