Peerless Industries PP730 사용자 설명서

다운로드
페이지 20
3 of 20
ISSUED: 10-01-07  SHEET #: 095-9272-2   06-15-09
C
AA
B
G
A
Before you begin, make sure all parts shown are included with your product.
Parts may appear slightly different than illustrated. 
Parts List
PP730
PP730-S
Description
Qty. Part #
Part #
AA wall arm assembly
1
095-P1630
095-4630
M4 x 12 mm phillips screw
4
504-9013
504-2014
M4 x 20 mm phillips screw
4
504-9020
504-2013
retaining spacer
4
590-5005
590-5003
#14 x 2.5" wood screws
2
520-1202
520-2165
5 mm allen wrench
1
560-9640
560-9640
concrete anchors
2
590-0320
590-0320
cable ties
2
560-9711
560-2004
cable tie anchor
1
590-1290
590-1290
3/16" allen wrench
1
560-0071
560-0071
8-32 x 1/4" flat head screw
1
520-1622
520-2622
E
I
Installation to Wood Stud Wall
•  Installer must verify that the supporting surface will
safely support the combined load of the equipment 
and all attached hardware and components.
•  Tighten wood screws so that wall plate is firmly at-
tached, but do not overtighten. Overtightening can
damage the screws, greatly reducing their holding 
power.
•  Never tighten in excess of 80 in. • lb (9 N.M.).
•  Make sure that mounting screws are anchored into the
center of the stud. The use of an "edge to edge" stud
finder is highly recommended.
•  Hardware provided is for attachment of mount through
standard thickness drywall or plaster into wood studs. 
Installers are responsible to provide hardware for 
other types of mounting situations (not UL approved). 
WARNING
Using a stud finder, locate and mark the edges of
the wood stud used in mounting this product. Use of 
an edge to edge stud finder is highly recommended.
Use a level to draw a vertical line down the center of 
the stud. Use wall plate as template to mark center 
of holes along the vertical line. Drill two 5/32" (4
mm) dia. holes 2.5" (64 mm) deep. Attach wall arm
assembly (
AA) to wall using two #14 x 2.5” flat head
wood screws (
D).
Skip to step 2.
1
D
WOOD STUD WALL
AA
H
M
D
F