VXi VT1529A/B 사용자 설명서

다운로드
페이지 529
VT1422A Command Reference   345
[SENSe]
[SENSe:]FUNCtion:HVOLtage 
[SENSe:]FUNCtion:HVOLtage [<range>,](@<ch_list>) 
links the specified 
VT1529B channels to return dc voltage on the high-level input (Excitation Sense + 
and -) pins on the RJ-45 connector for the channel.
This command is valid only on the VT1529B and is available with VXIplug&play 
driver revision A.01.09 or later (revision A.01.06 or later of hpe1422_32.dll).
Parameters
Comments
The VT1422A has five ranges: 0.0625 V dc, 0.25 V dc, 1 V dc, 4 V dc, and 
16 V dc. To select a range, simply specify the range value (for example, 4 selects 
the 4 V dc range). If a value is specified that is larger than one of the first four 
ranges, the VT1422A selects the next higher range (for example, 4.1 selects the 
16 V dc range). Specifying a value larger than 16 causes an error. Specifying 0 
selects the lowest range (0.0625 V dc). Specifying AUTO selects auto range. 
The default range (no range parameter specified) is auto range.
The VT1529A/B has a fixed gain of 32. Keep this in mind when <range> is set.
When Accepted: Not while INITiated
Related Commands: CAL:REMote?
*RST Condition: SENSE:FUNC:VOLT AUTO on all channels and bridges set 
to FBEN on all strain channels.
Send with VXIplug&play Function: hpe1422_cmd(...)
Usage
FUNC:HVOL  (@10000:10001)
Channels 0 - 1 measure high-level input 
voltage in auto-range (defaulted)
Parameter
Name
Parameter
Type
Range of
Values
Default 
Units
range
numeric (float32)
see comments
V dc
ch_list
channel list (string)
10000 - 15731
none