INITIAL SET-UP:
1.  Remove the air compressor from the carton.
2.  Read safety warnings before setting-up air compressor.  
3.  If  your  unit  contains  oil,  remove  the  oil  travel  plug  and  insert  the  oil  
 
dipstick.  Ensure the oil level in the air compressor pump is adequate.   
 
If low, add SAE non-detergent oil as recommended below:
 
 
Ambient Temperature 
SAE Viscosity
 
0-32°F 
 
 
SAE 10W
 
32-80°F 
 
 
SAE 20W
 
60-103°F 
 
 
SAE 30W
LOCATION:
1.  In order to avoid damaging the air compressor, do not incline the air 
 
compressor transversely or longitudinally more than 10°.
2.  Place air compressor at least 12 inches away from obstacles that may  
 
prevent proper ventilation.  Do not place air compressor in an area:
 
-where there is evidence of oil or gas leaks.
 
-where flammable gas vapors or materials may be present.
 
-where air temperatures fall below 32°F or exceed 104°F.
 
-where  extremely  dirty  air  or  water  could  be  drawn  into  the  air  
 
 compressor.
ELECTRICAL:
1.  USE OF AN EXTENSION CORD IS NOT RECOMMENDED because 
it could cause the compressor motor to overheat. It's preferable to use 
additional air hose instead of an extension cord.
2.  If use of an extension cord is unavoidable, be sure to use one heavy 
enough to carry the current your compressor will draw. Minimum cord 
sizes is as follows:
3.  Use only a 3-wire extension cord that has a 3-blade grounding plug and 
a 3-slot receptacle that will accept the plug on the compressor.
4.  Examine cords before using. Do not use the compressor if its cord is 
damages. Do not use a damaged extension cord.
5.  Keep cords away from heat and sharp edges. Do not pull on a cord to 
disconnect a plug -- grasp the plug.
6.  Always shut off the compressor Pressure Switch before unplugging the 
compressor. 
PRE-START CHECKLIST:
1.  Check oil level.  Add if necessary.
2.  Remove any moisture in the air compressor air tank.  
NEVER attempt  
 
to open the Air Tank Drain Valve when more than 10 PSI of air    
 
pressure is in the air tank!  Remove excessive pressure with an air  
 
tool, then open the Air Tank Drain Valve in the bottom of the air tank.   
 
Close tightly when drained.
3.  Make sure the Motor/Pressure Switch is in the "OFF" position.
4.  Make sure the Safety Relief Valve is working correctly.
5.  Make sure all guards and covers are in place and securely mounted.
PREPARATION INSTRUCTIONS
WARNING
RISK OF EXPLOSION OR FIRE 
CAUSING  SERIOUS  INJURY 
OR DEATH!
Do not allow the motor or Motor/
Pressure  Switch  to  come  in 
contact with  flammable vapors, 
combustible dust, gases or other 
combustible materials.  An electric 
spark  may  cause  an  explosion 
or fire.
When using the air compressor 
for spray painting, place the air 
compressor as far away from the 
work area as possible, using extra 
air  hoses  instead  of  extension 
cords.  
DANGER
RISK OF ELECTROCUTION! 
Improper  connection  of  the 
equipment-grounding conductor 
can result in a risk of shock or 
electrocution.    Check  with  a 
qualified  electrician  or  service 
personnel if you are in doubt as 
to whether the outlet is properly 
grounded.  Do not use any type 
of adapter with this product.  If 
repair  or  replacement  of  the 
cord  or  plug  is  necessary,  do 
not connect the grounding wire 
to either flat blade terminal.  The 
wire  with  insulation  having  an 
outer surface that is green with 
or  without  yellow  stripes  is  the 
grounding wire.
WARNING
RISK OF ELECTRICAL SHOCK!
This product must be grounded. If 
there should be a malfunction or 
breakdown, grounding provides 
a  path  of  least  resistance  for 
electric  current  to  reduce  the 
risk  of  electric  shock.    This 
product is equipped with a cord 
having an equipment-grounding 
conductor and a grounding type 
plug.  The plug must be plugged 
into an appropriate outlet that is 
properly installed and grounded 
in accordance with all local codes 
and ordinances.
 
WARNING
RISK OF BODILY INJURY! 
Never  attempt  to  open  the  Air 
Tank  Drain  Valve  when  more 
than 10 PSI of air pressure is in 
the air tank! 
 
Cord Length
Wire Gauge
Up to 25 Feet 
12 AWG
26 to 100 Feet
10 AWG
101 to 150 Feet
8 AWG
151 to 250 Feet
6 AWG