Siemens MC55 사용자 설명서

다운로드
페이지 469
MC55 AT Command Set  
5.6 AT+CPWD
s
m
obile
MC55_ATC_V01.05
Page 124 of 469
2/10/04
Confidential / Released
 
“PP“
Service Provider Personalisation 
“PC“
Corporate Personalisation 
Supplementary Service Call Barring:
Supplementary Service "Call Barring" allows to specify conditions under which calls will be disallowed by the
network.
The availability of the Supplementary Services varies with the network. To benefit from call barring the client will
need to subscribe them, though a limited number of call barring types may be included in the basic tariff pack-
age. 
: The Network Password needs to be supplied from the network provider or network oper-
ator. Usually there is one 4 digit password which applies to all call barring options. For details contact your pro-
vider. 
“AO“
BAOC (Bar All Outgoing Calls) 
“OI“
BOIC (Bar Outgoing International Calls) 
“OX“
BOIC-exHC (Bar Outgoing International Calls except to Home Country) 
“AI“
BAIC (Bar All Incoming Calls) 
“IR“
BIC-Roam (Bar Incoming Calls when Roaming outside the home country) 
“AB“
All Barring services 
“AG“
All outGoing barring services
“AC“
All inComing barring services
4...8
length of password. The range of permitted length for a password depends on
the associated 
. It is available from the test command response,
or in the description of parameter 
Password specified for the facility. 
Parameter 
 can be ignored if no old password was allocated to the facility. 
Take into account that a password may have already been set by factory, or that the service is subject to a pass-
word issued by the provider. See notes above or contact provider. 
New password. Mandatory, if 
 was an unblocking key (such as the Master Phone Code). 
Note
• To delete a password use the following syntax: 
at+cpwd=
 
Examples
EXAMPLE 1
 
 
To change PIN2 
<password length>
(num)
<old password>
(str)
<new password>
(str)
AT+CPWD="P2","0000","8888" 
(where "0000" = old PIN2 and "8888" = new PIN2) 
OK 