Siemens MC55 사용자 설명서

다운로드
페이지 469
MC55 AT Command Set  
7.13 ATS7
s
m
obile
MC55_ATC_V01.05
Page 156 of 469
2/10/04
Confidential / Released
 
7.13
ATS7 Set number of seconds to wait for connection completion
Syntax
Command Description
This parameter setting determines the amount of time to wait for the connection completion when answering or
originating a call. 
 Parameter Description
no. of seconds to wait for connection completion
000...060
(&F)
Notes
• Values bigger than 60 cause no error, but 
 will be set down to maximum value of 60.
• In 
 of 
 of the called party is set to higher values the call establishment may not be successful.
• The correlation between 
 and 
 is important.
Example: ATS7=30 and ATS0=20 may not allow call establishment.
Read Command
ATS7?
Response(s)
OK
Write Command
ATS7=
Response(s)
OK
PIN
ASC0
ASC1
MUX1
MUX2
MUX3
!
%
!
%
!
!
Reference(s)
V.25ter
<n>
(num)(&W)(&V)