MC55 AT Command Set  
8.7 AT^MONP
s
m
obile
MC55_ATC_V01.05
Page 202 of 469
2/10/04
Confidential / Released
 
there are several constraints to be considered: 
- Only neighbour cells that have already been visible in IDLE mode will be further updated, as long as they
are still included in the list.
- Though new neighbour cells can be added to the list (e.g. due to handover), their C1 and C2 parameters
cannot be displayed until the connection is released. In this case "-" is presented for C1 and C2.
- To some extent, the cell monitoring command 
 covers the same parameters. The receiving
level, for example, can be queried with both commands. Yet the resulting values may be slightly different,
even though obtained over a time period of a few seconds. This is quite normal and nothing to worry about,
as the cell information is permanently updated.
- For compatibility with earlier products and to support legacy applications, any input character may be used
to stop the output in certain cases (depending on the settings of 
 an
8.7.1
AT^MONP responses
Response of 
 (Example):
 
chann rs  dBm MCC MNC BCC  C1  C2
 653  26  -84 262  07   0  22  22
 660  20  -90 262  07   3  16  16
 687  19  -91 262  07   1  15  15
 678  14  -96 262  07   3  10  10
 671  14  -96 262  07   1  10  10
 643  10 -100 262  07   7   6   6
Column
Description
Chann 
ARFCN (Absolute Radio Frequency Channel Number) of the BCCH carrier
rs 
RSSI value 0 - 63 (RSSI = Received signal strength indication)
dBm 
Receiving level in dBm
MCC 
Mobile Country Code (first part of the PLMN code)
MNC 
Mobile Network Code (second part of the PLMN code)
BCC 
Base Station colour code
C1 
cell selection criterion
C2 