MC55 AT Command Set  
11.3 AT+FBADMUL
s
m
obile
MC55_ATC_V01.05
Page 285 of 469
2/10/04
Confidential / Released
 
11.3
AT+FBADMUL Error Threshold Multiplier
Syntax
Command Description
This command defines the "Copy-Quality-OK" multiplier. The number of lines received with a bad pixel count is
multiplied by this number. If the result exceeds the total number of lines on the page the error rate is considered
too high. A threshold multiplier value of 20 corresponds to a 5 per cent error rate. A value of 0 implies that error
checking is not present or disabled. 
 Parameter Description
0...20
(P)
...255
Note
• Used for Fax Class 2 only 
Read Command
AT+FBADMUL?
Response(s)
OK
Write Command
AT+FBADMUL=
 
Response(s)
OK
If error is related to ME functionality:
ERROR
PIN
ASC0
ASC1
MUX1
MUX2
MUX3
!
%
!
%
!
!
Reference(s)
EIA PN-2388
<badmul>
(num)