MC55 AT Command Set  
11.27 AT+FTS
s
m
obile
MC55_ATC_V01.05
Page 310 of 469
2/10/04
Confidential / Released
 
11.27
AT+FTS Stop Transmission and Wait
Syntax
Command Description
This command causes the TA to terminate a transmission and wait for 
 10 millisecond intervals before
responding with the OK result code to the DTE. 
 Parameter Description
no. of 10 millisecond intervals 
0...85
Note
• Used for Fax Class 1 only 
Write Command
AT+FTS=
Response(s)
An ERROR response code results if this command is issued while the modem is on-
hook.
PIN
ASC0
ASC1
MUX1
MUX2
MUX3
!
%
!
%
!
!
Reference(s)
TIA/EIA-578
<time>
(num)