Siemens MC55 사용자 설명서

다운로드
페이지 469
MC55 AT Command Set  
17.4 AT^SBV
s
m
obile
MC55_ATC_V01.05
Page 433 of 469
2/10/04
Confidential / Released
 
17.4
AT^SBV Battery/Supply Voltage
Syntax
Command Description
The exec command allows to monitor the supply (or battery) voltage of the module measured on pin BATT+. The
reference point for measuring the voltage are the test points BATT+ and GND on the bottom of the module. Refer
to [1] for information on the module's test points. 
The displayed value is constant over the measurement period. The duration of the measurement period depends
on the operating mode on the radio interface: it ranges from 0.5s in TALK / DATA mode up to 50s when MC55
is in IDLE mode or Limited Service (deregistered). 
 Parameter Description
supply (or battery) voltage in mV
Test Command
AT^SBV=?
Response(s)
OK
ERROR
+CME ERROR:
Exec Command
AT^SBV
Response(s)
^SBV: 
OK
ERROR
+CME ERROR:
PIN
ASC0
ASC1
MUX1
MUX2
MUX3
!
%
%
%
%
%
Reference(s)
SIEMENS
<value>
(num)