MC55 AT Command Set  
4.5 ATE
s
m
obile
MC55_ATC_V01.05
Page 93 of 469
2/10/04
Confidential / Released
 
4.5
ATE Enable command echo
Syntax
Command Description
This setting determines whether or not the TA echoes characters received from TE during command state. 
 Parameter Description
[0]
Echo mode off
1
(&F)
Echo mode on
Note
• In case of using the command without parameter, 
 is set to 0.
Exec Command
ATE
Response(s)
OK
PIN
ASC0
ASC1
MUX1
MUX2
MUX3
!
%
%
%
%
%
Reference(s)
V.25ter
<value>
(num)(&W)(&V)