Siemens MC55 사용자 설명서

다운로드
페이지 469
MC55 AT Command Set  
4.7 AT+IPR
s
m
obile
MC55_ATC_V01.05
Page 96 of 469
2/10/04
Confidential / Released
 
4.7
AT+IPR Set fixed local rate
The comman
 can be used to set or query the DTE-DCE interface bitrate. 
Syntax
Command Description
The test command returns the values of the supported automatically detectable bitrates and the values of the
supported fixed-bitrates. 
The read command returns the current bitrate of the interface. 
The write command specifies the bitrate to be used for the interface. When you set a fixed-rate, make sure that
both DTE (TE) and DCE (TA) are configured to the same rate. When you select autobauding, the DCE will auto-
matically recognize the bitrate currently used by the DTE. 
A selected bitrate takes effect following the issue of any result code associated with this command (e.g. OK). 
The setting is stored in the non-volatile memory and will be used whenever the engine is powered up again. How-
ever, in case of autobaud mode (
=0) the detected DCE bitrate will not saved and, therefore, will resyn-
Test Command
AT+IPR=?
Response(s)
+IPR: 
(list of supported auto-detectable 
s) , (list of supported fixed-only 
s) 
OK
Read Command
AT+IPR?
Response(s)
+IPR: 
OK
Write Command
AT+IPR=
Response(s)
OK
ERROR
+CME ERROR
PIN
ASC0
ASC1
MUX1
MUX2
MUX3
!
%
§
§
§
§
Reference(s)
V.25ter