If  you  only  want  to  change  value  of  output  regardless  of  previous  state  send 
command without parameter “y” – e.g. XXppppOUT5 changes value of output No. 
5 to reverse. 
 
Newly  set  actual  values  of  all  8  inputs/outputs  are  sent  back  to  sender  and  to 
INFOSMS number. 
 
 
 
4.11. LIST – Detection of Set-up 
 
If you want to find out which values of parameters are set in GB 051 it is possible 
to  send  control  SMS  message,  which  initiates  sending  messages  with  detailed 
description of set-up back to sender. 
 
 
Command 
XXppppLIST
Vi 
*1)
 
pppp 
Four digits of current PIN 
IO  number:  1  to  8,  with  no  parameter  will  return  the 
shared configuration  
*
1) The space is between key word of command “LIST” and “i” 
 
SMS  command  messages  intended  for  getting  parameter  configuration  of  each 
input/output 1–8: 
The  GB 051  unit  will  return  sender  a  message  with  the  required  configuration 
information related to the particular IO: 
  Actual value of logical level of the particular input.   
 
  Pre-set phone number for ALARM call.  
 
 
 
 
  Pre-set number A for ALARM SMS for the particular input.   
  Pre-set SMSNO B for the input. 
  Pre-set SMSTXT – text of the message of the input. 
 
 
 
 
IO value, acall, aSMSnoA, aSMSnoB, SMStxt 
 
In case the command SMS message is sent with no parameter, the GB 051 unit 
will respond to the sender with message containing five basic configuration data: 
  
infoSMS number, infoSMS interval, icall number, icall interval, mcall number 
 
4.12. CALLBACK – Monitoring of Protected Area 
 
If  you  want  to  find  out  by  listening  –  e.g.  during  alarm  –  what  is  happening  in 
place of installation it is possible to require, by SMS message, to get further call 
from GB 051 with switched-on microphone for room monitoring. 
 
Command 
*1)
 
XXppppCALLBACK
Vnumber 
pppp 
Four digits of current PIN 
Number 
Maximum 14 digits of any phone number 
*2)
 
 
 
*1) The space is between key word of command „CALLBACK“ and number. 
 
 
*2)  If  no  number  is  specified  GB  051  calls  back  the  number  of  sender  of  SMS command. 
Number  can  be  entered  in  national  format –  e.g.  606445566  but  also  in  international 