Siemens Mux_guide_v06 사용자 설명서

다운로드
페이지 36
Multiplexer User's Guide 
Confidential / Released 
s
 
m
o
 
b
 
i
 
l
 
e
 
Mux_guide_v06 
Page 11 of 36 
30.06.2004 
3  Integrating multiplexer into the customer application 
When designing a multiplexer application, you can create your own sources or take 
advantage of the sources delivered upon request by Siemens. The Siemens sources are 
packed in a *.zip file which includes a driver for Windows 2000 and Windows XP. See [5] for 
a detailed description. 
3.1 Characteristics 
After establishing the multiplexer mode according to the multiplexer protocol, three logical 
channels are available. Please keep the following restrictions and requirements in mind: 
 
3.1.1 Basic requirements 
•  The GSM engine supports the basic option and UIH Framing according to GSM 07.10. 
•  Character
 
framing
 
must
 
be
 
configured
 
for
 
8
 
data
 
bits,
 
no
 
parity
 
and
 
1
 
stop
 
bit. 
If you wish to use multiplexer mode with TC35i modules, be sure not to change this 
setting. 
•  Hardware flow control AT\Q3 is recommended for use with multiplexer mode. If used, it 
needs to be set before multiplexer mode is entered. 
•  Several customer software applications may be able to change the selected settings. 
These settings will be stored in the non-volatile memory and used whenever the module 
is powered up again. In this case the multiplexer fails to start. To avoid this, it is recom-
mended to re-synchronize all settings before using the multiplexer mode again. 
•  Before closing the multiplexer make sure that there is no ongoing activity on one of the 
channels. For example, check that voice, CSD or GPRS connections have ended and 
wait until all pending AT command  responses are received. 
 
 
3.1.2 Restrictions 
If the GSM engine is operated in multiplexer mode, the following restrictions apply: 
•  MO and MT circuit-switched data and fax calls can only be set up on channel 1. 
•  It is not recommended to use AT+CFUN=<n> for selecting one of the SLEEP modes. For 
products supporting Multiplexer Protocol version 3, the best approach to properly control 
SLEEP mode in this case is to issue the PSC messages described in Chapter 4.3.10. 
 
The multiplexer cannot be started if one of the following features is activated, nor can these 
features be used when multiplexer is active: 
•  Multiplex mode cannot be started while autobauding (AT+IPR=0) is enabled.  
•  The multiplexer is not available in charge-only mode and in alarm mode. 
•  XON/OFF flow control is not supported in multiplexer mode. 
 
The maximum frame size N1 (defined in GSM 07.10) is fixed to 98 bytes and cannot be 
changed. The maximum frame size is the same for sending and receiving. See also Chapter 
4 in this manual and GSM 07.10.