4.3.10 Power saving control (PSC) 
The power saving control message uses the following type field octet: 
 
Type:  
Bit 1 
Bit 2 
Bit 3 
Bit 4 
Bit 5 
Bit 6 
Bit 7 
Bit 8 
1 C/R 
0 1 0 
 
 
 
C/R bit:  Indicates whether the sequence is a command or a response. 
 
Length: 
The length byte contains the value 0 (no value octet) or 1 (one value octet).  
 
 
Value octet (Length=1) 
Bit 1 
Bit 2 
Bit 3 
Bit 4 
Bit 5 
Bit 6 
Bit 7 
Bit 8 
P1  P2 P3 P4 0  0  0  0 
 
The P-bits are defining the parameter value. 
 
In commands:  
Bit 1 
Bit 2 
Bit 3 
Bit 4 
Description 
Switches to the same mode as without a 
value octet 
1  0 0 0 Switches 
into 
full 
functionality 
mode, 
like 
AT+CFUN=1 
Switches into NON-CYCLIC SLEEP mode, 
like AT+CFUN=0 
Switches into CYCLIC SLEEP mode, like 
AT+CFUN=5 
Switches into CYCLIC SLEEP mode, like 
AT+CFUN=6 
1  0 1 0 Switches 
off, 
like 
AT^SMSO 
0  1 1 0 Resets, 
like 
AT+CFUN=1,1 
 
Switches into CYCLIC SLEEP mode, like 
AT+CFUN=7 
Switches into CYCLIC SLEEP mode, like 
AT+CFUN=8 
 
All wake up events and details of the CYCLIC and NON-CYCLIC SLEEP mode are specified 
in [2]. 
 
In responses: 
Bit 1 
Bit 2 
Bit 3 
Bit 4 
Description 
0  0 0 0 Failure 
1  0 0 0 Success 
 
 
Figure 12: Power Saving Control (PSC)