Motorola WT4090 사용자 설명서

다운로드
페이지 94
1 - 6
WT4070/90 Wearable Terminal User Guide
Charging the Battery
Charging the Main Battery and Memory Backup Battery
Before using the wearable terminal for the first time, charge the main battery until the amber Charge Status LED 
remains lit (see 
 for charge status indications).
The wearable terminal is equipped with a memory backup battery which automatically charges from the main 
battery whether or not the wearable terminal is operating or is in suspend mode. The memory backup battery 
retains data in memory for at least 30 minutes when the wearable terminal's main battery is removed or fully 
discharged. When the wearable terminal is used for the first time or after the memory backup battery has fully 
discharged, the memory backup battery requires approximately 15 hours to fully charge. Do not remove the main 
battery from the wearable terminal for 15 hours to ensure that the memory backup battery fully charges. If the main 
battery is removed from the wearable terminal or the main battery is fully discharged, the memory backup battery 
completely discharges in several hours.
When the wearable terminal reaches a very low battery state, the combination of main battery and backup battery 
retains data in memory for at least 24 hours.
Charge the wearable terminal with an installed main battery using either the Single Slot USB cradle or the Four Slot 
Ethernet cradle.
To charge the main battery:
1.
Ensure the cradle used to charge the main battery is connected to the appropriate power source.
2.
Insert the wearable terminal into a cradle.
3.
The wearable terminal starts to charge automatically. The amber Charge Status LED lights to indicate the 
charge status. Se
 for charging indications. The standard capacity battery fully charges in less than 
four hours.
CAUTION
Ensure that you follow the guidelines for battery safety described in 
NOTE
Do not remove the main battery within the first 15 hours of use. If the main battery is removed before the 
backup battery is fully charged, data may be lost.
Table 1-3    
Wearable Terminal LED Charge Indicators
LED
Indication
Off
Wearable terminal is not in cradle. Wearable terminal not placed correctly. Charger is not 
powered.
Fast Blinking Amber
Charging error:
Temperature is too low or too high.
Charging has gone on too long without completing (typically eight hours).
Slow Blinking Amber
Wearable terminal is charging.
Solid Amber
Charging complete.
Note: When the battery is initially inserted in the wearable terminal, the amber LED flashes 