Panasonic MN101C00 사용자 설명서
![Panasonic](https://files.manualsbrain.com/attachments/8f677e63fb64cbb6c62d09e6242996e7631380a8/common/fit/150/50/34d700d3fb727c767799b2da5cc474b219c0a4312e9e3044c99491a2fb9a/brand_logo.png)
Chapter 4 Timer Functions
85
Timer Function Control Registers
4-9-3 Timer Mode Registers
Four readable and writable 6-byte timer mode registers. Control timers 2, 3, 4, 5, and
the time base.
(1) Timer 2 mode register (TM2MD)
Figure 4-9-13 Timer 2 Mode Register (TM2MD: X'03F82', R/W)
0
1
2
4
5
6
7
3
(at reset: ---00XXX)
–
–
–
TM2MD
TM2CK0
TM2CK1
TM2CK2
0
1
1
X
1
0
0
0
0
1
1
0
1
1
Normal timer operation
TM2 operation mode selection
TM2 count control
PWM operation
TM2CK0
TM2CK1
TM2CK2
TM2PWM
TM2EN
fs
fs/4
fx *
TM2IO input
Synchronous fx *
Synchronous TM2IO input
Clock source selection
TM2PWM
0
1
Halt the count
Operate the count
TM2EN