Siemens LC 500 사용자 설명서

다운로드
페이지 122
Page 96
SITRANS LC 500 – INSTRUCTION MANUAL
7ML19985GE01
mmmmm
Appendix F
Appendix F: Approvals
CE Certificate
WRITTEN 
 DECLARATION OF CONFORMITY
We,
Siemens Milltronics Process Instruments B.V.
       
Nikkelstraat 10 - 4823 AB BREDA - The Netherlands
Declare, solely under own responsibility, that the product
Capacitance Level and Flow Measurement/Detection, 
SITRANS LC 500 / Pointek CLS 500
Mentioned in this declaration, complies with the following standards and/or 
normative documents:
Requirements
Remarks
Certificate No
Environment
Commercial, light Industrial and industrial
2008949-KRQ/EMC 01-4231
EN 61326: 1998
Product group standard for “Electrical equipment 
for measurement, control and laboratory use”,
from which: 
 EN 50011 : 1998
Emission – Class B
  EN 61000-4-2: 1995
Electrostatic Discharge (ESD) Immunity
  EN 61000-4-3: 1996
Radiated Electro-Magnetic Field Immunity
  EN 61000-4-4: 1995
Electrostatic Fast Transient (EFT) Immunity
  EN 61000-4-5: 1995
Surge Transient  Immunity
  EN 61000-4-6: 1996
Conducted Radio-Frequency Disturbances Immunity
ATEX Directive 94/9/EC
Audit Report No 2003068
KEMA 00ATEXQ3047
           II 1 G EEx ia IIC T4…T6 
 0344
KEMA 02ATEX1019 X
II 1/2 GD EExd  [ia] IIC T6…T1 
 0344 
KEMA 01ATEX2076 X
II 3 GD EEx nA [ib] IIC T4…T6 
 0344
KEMA 02ATEX1033 X
T 100 °C  IP 66
EN 50014: 1992
General Requirements 
EN 50018: 1994
Flameproof Enclosures “d” 
EN 50020: 1994
Intrinsic Safety “i”
EN 50284: 1999
Special Requirements for Category 1G Equipment 
EN 50281-1-1: 1998
Dust Ignition Proof 
The notified body :  N.V. KEMA – Utrechtseweg 310 – 6812 AR Arnhem – The Netherlands
97/23/EC  
      Pressure Equipment Directive
Lloyd’s Register, DAD No.:
8033474, 8033475, 8033476, 
8033477, 8033478, 8033479, 
8033480, 8033481, 8033482, 
8033483, 8033484, 8033485 
The notified body :  Stoomwezen B.V. – Weena Zuid 168 – 3012 NC Rotterdam - The Netherlands
Location,
Breda
Representative Name,
C.S. van Gils 
Date,
August 28th, 2002
Function,
Managing Director
Remark:
For specific safety specifications, please consult the instrument label