Mitsubishi Electronics M700V 사용자 설명서

다운로드
페이지 214
Appendix 1 Cable
MITSUBISHI CNC
128
Appendix 1.11 DG24 Cable
Max. cable length:  10m
Application: 5V spply/DO output cable (For drive unit - battery box)
(Note)
The battery box side is connected using a bare conductor or a terminal bar.
<DG24 cable connection diagram (Connection cable for alarm output between drive unit and MDS-BTBOX-36)>
(For MDS-D2/DH2)
<DG24 cable connection diagram (Connection cable for alarm output between drive unit and MDS-BTBOX-36)>
(For MDS-DM2)
20 
13 
 
FG 
DICOM
D11
P5
LG
+24V
DO(ALM)
+5V
LG
0.2mm
2
 
:10120-3000VE
:10320-52F0-008
0.2mm
2
 
0.2mm
2
 
Case
grounding
(DC power)
Drive unit side connector
Connector
Shell kit
Battery box side
Blue
Yellow
Light blue
White
20 
13 
 
FG 
DICOM
D11
P5
LG
24G
DOCOM
+5V
LG
0.2mm
2
 
:10120-3000VE
:10320-52F0-008
0.2mm
2
 
0.2mm
2
 
Case
grounding
(DC power)
Drive unit side connector
Connector
Shell kit
Battery box side
Blue
Yellow
Light blue
White