BATTERIES 
The P7200 and P5200 series portable radios use rechargeable, recyclable Nickel Cadmium (NiCd), Nickel 
Metal Hydride (NiMH), or Lithium Ion (Li Ion) batteries. Please follow the directions below to maximize 
the useful life of each type of battery. 
 
 
Do not disassemble or modify Lithium Ion battery packs. The Lithium Ion battery 
packs are equipped with built-in safety and protection features. Should these 
features be disabled or tampered with in any way, the battery pack can leak acid, 
overheat, emit smoke, burst, and/or, ignite. 
 
 
If the battery is ruptured or is leaking electrolyte that results in skin or eye contact 
with the electrolyte, immediately flush the affected area with water. If the battery 
electrolyte gets in the eyes, flush with water for 15 minutes and consult a physician 
immediately. 
4.1  CONDITIONING BATTERY PACKS 
4.1.1 
Conditioning NiMH Battery Packs 
Condition a new NiMH battery before putting into use. This also applies to rechargeable NiMH batteries 
that have been stored for long periods (weeks, months, or longer). Conditioning requires fully charging 
and fully discharging the battery three (3) times using a “battery analyzer/conditioner/charger.” M/A-
COM recommends either the Cadex
®
 C7400 or the Intelligent Technologies Co. BC3506QP-5 iTECH
®
 
iQ
five®
 battery conditioners, purchased directly from M/A-COM. These units condition a battery pack by 
automatically charging and discharging (cycling) the battery.   
CAUTION
 
Failure to properly condition NiMH battery packs before initial use will result in 
shortened performance by the battery. 
4.1.2 
Conditioning NiCD Battery Packs 
A new NiCD battery does not require conditioning before use. Periodically condition NiCD batteries to 
avoid the memory effect. If a NiCD battery is repeatedly charged and not fully discharged, the result is 
lower voltage and lower capacity. Fortunately, both voltage and capacity are restored through battery 
conditioning.    
CAUTION
 
Always use M/A-COM authorized chargers and conditioners. Use of unauthorized 
chargers and conditioners may void the warranty. 
4.1.3 
Additional Information 
For more information regarding the proper care of portable radio batteries or establishing a battery 
maintenance program, refer to ECR-7367 which may be ordered by calling toll free 1-800-368-3277, then 
selecting option 7.