Tyco Electronics P5200 사용자 설명서

다운로드
페이지 122
MM23772, Rev. F 
37 
8.13  KEYPAD 
8.13.1 
Keypad Function Commands (P7270 Only) 
To perform a command from the keypad, use one of the keypad commands: 
Table 8-5: Keypad Function Commands 
KEYPAD 
COMMAND 
FUNCTION 
*0 
Log-off command:  *0## (logs the user off the system). See Section 8.7 for additional 
information. 
*1 
Log-in command:  *1<User ID> # <Password> ## (required for encryption). See Section 
8.6 for additional information. 
*4 
Enter Scene of Incident Mode (SOI) on specified channel and band: 
*4#<ccc>#<bb># 
where ccc is the SOI channel number and bb is the number assigned to each frequency 
band. Refer to 8.31.5 for more information. 
Press *40# to exit SOI mode. 
*7 
Initiate Selective Alert command:
 *7<Target ID>#[Choose Message]#. See Section 8.25 
for additional information. 
*8 
Radio-to-Radio Call command:  *8<Selective call number># (PTT to dial).  
*9 
Public Switched Telephone Network (PSTN) Call command: 
*9 <telephone number># 
(PTT to dial).
  
*32 
Begin Manual Encryption command:  *32<Pre-determined Encryption Key>#    
1 – 16 digit encryption key for 128 bit encryption; 17 – 32 digit encryption key for 256 bit 
encryption. Refer to Section 0 for more information. 
*33 
End Manual Encryption command:  *33# 
*61 
Initiate XCOV Mode command:
 *61# 
*62 
Initiate XCOV-TG Mode command:
 *62# 
Extended coverage for a talk group. Refer to 8.31.1 for more information. 
*60 
Exit XCOV or XCOV-TG Mode: *60# 
Returns to the normal mode. Refer to 8.31.1 for more information.