Location Requirements
The tumbler must be installed on a level floor capable 
of supporting 120 lbs./ft
2
 (585.8 kg/m
2
). Floor 
covering materials such as carpeting or tile should be 
removed.
To assure compliance, consult local building code 
requirements.
The tumbler MUST NOT be installed or stored in area 
where it will be exposed to water and/or weather.
IMPORTANT: DO NOT block the airflow at the 
rear of the tumbler with laundry or other articles. 
Doing so would prevent adequate air supply to the 
combustion chamber of the tumbler.
A typical tumbler enclosure is shown in Figure 1. Note 
that the enclosure touches the tumbler top and side 
panels. Also, note the minimum and maximum 
dimensions. Local codes and ordinances must be 
complied with.
IMPORTANT: Install tumblers with sufficient 
clearance for servicing and operation. Refer to 
Figure 1
Figure 1 
To reduce the risk of serious injury, install 
lockable door(s) to prevent public access 
to rear of tumblers.
W055
WARNING
TMB237N
NOTE: Shaded areas indicate adjacent structure.
1
Zero clearance permitted for first 4 in. (102 mm)
2
4 in. (102 mm) 
3
Minimum clearance permitted for remainder: Gas 4 in. (102 mm), Steam 12 in. (305 mm)
4
Guard
5
Provision for Make-Up Air
6
24 in. (610 mm) Minimum, 36 in. (914 mm) recommended for maintenance purposes
7
Zero Clearance
3
1
4
5
6
7
2
WARNING
To reduce the risk of severe injury, clearance of tumbler cabinet from combustible 
construction must conform to the minimum clearances.
W056