Sterling SCD 10 사용자 설명서

다운로드
페이지 30
10 CFM Compressed Air Dryer 
Chapter 3: Installation 
18 of 30 
 
3-6  Installing the Remote-Mount Membrane Dryer (Optional) 
The membrane drying kit can be mounted anywhere near the compressed air dryer.  The kit is 
pre-assembled with a bracket that can be mounted to any flat surface with two screws.  Use 
Figure 5 as a reference for this installation. 
1. 
Remove the large particle filter, including the close nipple, from the inlet of the 
compressed air dryer.  
2.  Attach the large particle filter (including the close nipple) to the membrane drying kit. 
Note:  The membrane drying kit must have the large particle and the coalescing filters 
in place and functioning properly to ensure full drying capabilities of the 
membrane. Both filters must be checked and cleaned regularly.  
3. 
Attach the 1/4” NPT elbow to the inlet of the compressed air dryer. 
4. 
Run the 3/8” hose between the outlet of the membrane drying kit and the inlet of the 
compressed air dryer. Use thread sealant on all threaded connections. 
Figure 5: Membrane Dryer Assembly