Electrical Requirements
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING
120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical 
supply is required. A time-delay fuse or circuit breaker is 
recommended. It is also recommended that a separate circuit 
serving only this dryer be provided.
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
■  
For a grounded, cord-connected dryer: 
This dryer must be grounded. In the event of malfunction or 
breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This dryer is equipped with a cord having an 
equipment-grounding conductor and a grounding plug. The 
plug must be plugged into an appropriate outlet that is 
properly installed and grounded in accordance with all local 
codes and ordinances.
WARNING: 
Improper connection of the 
equipment-grounding conductor can result in a risk of 
electric shock. Check with a qualified electrician or service 
representative or personnel if you are in doubt as to 
whether the dryer is properly grounded. Do not modify the 
plug provided with the dryer: if it will not fit the outlet, have 
a proper outlet installed by a qualified electrician.
Gas Supply Requirements
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 13" (330 mm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Gas Type
Natural gas:
This dryer is equipped for use with Natural gas. It is design-
certified by CSA International for LP (propane or butane) gases 
with appropriate conversion.
Your dryer must have the correct burner for the type of gas in 
your home. Burner information is located on the rating plate 
in the door well of your dryer. If this information does not 
agree with the type of gas available, contact your dealer or 
call the phone numbers referenced in the “Assistance or 
Service” section. 
LP gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the appliance from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting your gas company.
Gas supply line
Must include 
1
/
8
" NPT minimum plugged tapping accessible 
for test gauge connection, immediately upstream of the gas 
connection to the dryer (see illustration).
½" IPS pipe is recommended.
3
/
8
" approved aluminum or copper tubing is acceptable for 
lengths under 20 ft (6.1 m) if local codes and gas supplier 
permit.
If you are using Natural gas, do not use copper tubing.
Lengths over 20 ft (6.1 m) should use larger tubing and a 
different size adapter fitting.