Installation Instructions
Electrical connection (non-Canada) - 3 wire cord
Turn off power supply to outlet. 
1. 
Remove the screw securing the terminal block 
2. 
access cover in the lower corner on the back of 
the dryer.
Install a UL-approved strain relief according 
3. 
to the power cord/strain relief manufacturer’s 
instructions in the power cord entry hole below 
the access panel. At this time, the strain relief 
should be loosely in place.
Thread an UNPLUGGED, UL-approved, 30 amp.
4. 
power cord, NEMA 10-30 type SRDT, through the
strain relief.
Attach the power cord neutral (center wire)
5. 
conductor to the SILVER colored center 
terminal on the terminal block. Tighten the 
screw securely.
Attach the remaining two power cord outer 
6. 
conductors to the outer, BRASS colored
terminals on the terminal block. Tighten both 
screws securely.
       WARNING
ELECTRICAL SHOCK HAZARD
Do not make a sharp bend or crimp wiring/   
                          
conductor at connections.
3-wire receptacle
(NEMA type 10-30R)
Internal ground
(GREEN screw)
Install
UL-approved
strain relief here
Terminal screw
recovery slot
Line 1
(BRASS terminal)
Neutral
(SILVER terminal)
Line 2
(BRASS terminal)
Access cover
screw
Terminal
block
Neutral
(center wire)
30 AMP
NEMA 10-30
       NOTE
If a terminal screw falls during cord installation, 
it can be retrieved in the terminal screw recovery 
slot below the access panel.
       WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source before servicing 
could result in personal injury or even death.
Follow manufacturer’s guidelines for firmly 
7. 
securing the strain relief and power cord. 
Reinstall the terminal block cover.
8. 
DO NOT remove
internal ground in
a 3-wire system!!
Neutral
terminal
IMPORTANT
If moving dryer from a 4-wire system and 
installing it in a 3-wire system, move the internal 
ground from the center terminal back to the 
GREEN screw next to the terminal block.