Global Call API for HMP on Windows Programming Guide — August 2006
Real Time Configuration Management
the target object is located. The customer application must ensure that the target object and 
requested parameters match. 
9.2.3
RTCM Parameters
The third component of the RTCM feature are the RTCM Parameters. The parameters are defined 
and maintained in four categories of software modules: Global Call Library (GCLib), Call Control 
Library (CCLib), Protocol and Firmware. Each software module supports different target objects as 
well as the target objects’ parameters. 
9.3
Using RTCM Parameters
The Global Call RTCM provides a generic way of getting (E1, T1 and ISDN technologies) and 
setting (all technologies) the configuration information for a target object. The target objects and 
their parameters are defined and maintained in the following categories of software modules: 
Parameters in GCLib Module 
parameters that are defined in GCLib. These parameters are common across multiple 
technologies, such as protocol name and ID, call event mask, and the call state mask of a line 
device. Although the GCLib module maintains many of the GCLib-defined parameters, some 
parameters, such as calling number and call info, are maintained in other modules (such as 
CCLib). 
Parameters in CCLib Module 
parameters that are defined and maintained in the CCLib module. The CCLib may maintain 
some GCLib-defined parameters, such as calling number and call info. See the appropriate 
Global Call Technology Guide for more information about configurable parameters. 
Parameters in Protocol Module 
parameters that are defined and maintained in a protocol module. One example of protocol 
parameters are country dependent parameters (CDP). See the appropriate Global Call 
Technology Guide for more information about configurable parameters. 
Parameters in Firmware Module 
parameters that are defined and maintained in a firmware module. See the appropriate Global 
Call Technology Guide for more information about configurable parameters. 
To access the value of a parameter, the application must specify a four-part name consisting of two 
pairs: (target object type, target object ID) and (set ID, parameter ID). 
Target object type and target object ID 
This pair represents the target object. See 
information. Both the target object type and target object ID are specified as the first two 
arguments to the Global Call RTCM API function. An example of a target object is 
(GCTGT_CCLIB_CHAN, Global Call line device ID). 
Set ID and parameter ID 
This uniquely represents a parameter within a specified target object. See 
, on page 114 for more information. A set ID typically 
represents a group of parameters that are closely related and are maintained in the same 
software module. The parm ID represents a parameter within a given set ID. In general,