Intel 05-2409-003 사용자 설명서

다운로드
페이지 154
Global Call API for HMP on Windows Programming Guide — August 2006
91
Call Control
CCPARM_CA_PAMD_QTEMP 
PAMD Qualification Template. Specifies which PAMD template to use. Possible values are: 
PAMD_QUAL1TMP – First predefined qualification template. This is the default value. 
-1 –  No qualification template 
Setting CCPARM_CA_PAMD_QTEMP to a value of PAMD_QUAL2TMP is not supported. 
Note:
The CCPARM_CA_PAMD_QTEMP parameter can also be set to a qualification template ID that 
is defined in the CONFIG file. 
CCPARM_CA_PVD_QTEMP 
PVD Qualification Template. Specifies which PVD template to use. Possible values are: 
PAMD_QUAL1TMP – First predefined qualification template. This is the default value. 
-1 – No qualification template 
Setting CCPARM_CA_PVD_QTEMP to a value of PAMD_QUAL2TMP is not supported. 
Note:
The CCPARM_CA_PVD_QTEMP parameter can also be set to a qualification template ID that is 
defined in the CONFIG file. 
By default, qualification template parameters are set to the most common values. However, it is 
possible to tune these parameters in the CONFIG file as described in Technical Note 030 available 
on the Customer Support web site at: 
. The technical note is not 
written specifically for HMP, but the same principle applies.
Note:
DM/IP boards use a slightly different version of the PVD/PAMD qualification templates; the 
values are adjusted for gain loss. CONFIG files for DM/IP boards do include PVD/PAMD 
qualification templates. 
7.2.5
Configuring Call Progress Analysis on a Per Channel Basis 
Global Call also supports the setting of call progress analysis parameters on a per channel basis. 
When call progress analysis parameters are set on a per channel basis, the parameter settings apply 
to all calls made on that channel (line device). 
To specify call progress analysis behavior on a per channel basis, use the gc_SetConfigData( ) 
function. The relevant function parameters and values in this context are: 
target_type 
GCTGT_CCLIB_CHAN 
target_id 
the line device 
target_datap 
a pointer to a GC_PARM_BLK structure that contains the following parameter set ID and 
parameter IDs: 
SetId  – CCSET_CALLANALYSIS 
ParmId  – CCPARM_CA_MODE that can take any of the values described in 
In earlier releases, when using CAS PDK protocols, it was possible to specify call progress and call 
analysis on a per channel basis using the gc_SetParm( ) function to enable or disable the