VIVOTEK FD6111V 사용자 설명서

다운로드
페이지 91
 
 
 
 
 
 
 
 
 
 
- 79 - 
 
www.vivotek.com 
T: 886-2-82455282 
F: 886-2-82455532 
 
 
 
Syntax: 
http://<servername>/cgi-bin/setdo.cgi?do1=<state>[&do2=<state>] 
[&do3=<state>][&do4=<state>][&return=<return page>
 
Where state is H, L. H means NC (normal close) connected with COMMON and L 
means NO (normal open) connected with COMMON. The number of DO dependents 
on the server type. 
 
parameter Value 
description 
H – NC connected with COMMON 
do<num> 
<state> 
L – NO connected with COMMON 
return 
<return page> 
Redirect to the page <return page> after the 
parameter is assigned. The <return page> can 
be a full URL path or relative path according the 
the current path. If you omit this parameter, it 
will redirect to an empty page. 
 
Example: Drive the digital output 1 to high and redirect to an empty page 
http://myserver/cgi-bin/setdo.cgi?do1=H
 
 
Query status of the digital input 
Note: This request requires the privilege of I/O access control. 
Method: GET/POST 
 
Syntax: 
http://<servername>/cgi-bin/getdi.cgi?[di1][&di2][&di3][&di4] 
 
If no parameter is specified, all the status of digital input will be returned. 
 
Return: