317
Choose U Face detection on to enable face detection when 
shooting portraits with matrix metering during viewfinder 
photography (0 114).
When calculating exposure, center-weighted metering assigns 
the greatest weight to a circle in the center of the frame. The 
diameter (φ) of this circle can be set to 8, 12, 15, or 20 mm or to 
the average of the entire frame.
Note that when a non-CPU lens is used, the area assigned the 
greatest weight for center-weighted metering is equivalent to a 
circle with a diameter of 12 mm, regardless of the setting 
selected for Non-CPU lens data in the setup menu (0 229).
A
Show ISO/Easy ISO
Custom Setting b4 (Easy exposure compensation) can not be used 
with Custom Setting d8 (ISO display and adjustment) > Show ISO/
Easy ISO (0 325). Adjustments to either of these items reset the 
remaining item; a message is displayed when the item is reset.
b5: Matrix Metering
G
 button ➜ A Custom Settings menu
b6: Center-Weighted Area
G
 button ➜ A Custom Settings menu